Generalization of Video-Based Heart Rate Estimation Methods To Low Illumination and Elevated Heart Rates

Heart rate is a physiological signal that provides information about an individual's health and affective state. Remote photoplethysmography (rPPG) allows the estimation of this signal from video recordings of a person's face. Classical rPPG methods make use of signal processing techniques, while recent rPPG methods utilize deep learning networks. Methods are typically evaluated on datasets collected in well-lit environments with participants at resting heart rates. However, little investigation has been done on how well these methods adapt to variations in illumination and heart rate. In this work, we systematically evaluate representative state-of-the-art methods for remote heart rate estimation. Specifically, we evaluate four classical methods and four deep learning-based rPPG estimation methods in terms of their generalization ability to changing scenarios, including low lighting conditions and elevated heart rates. For a thorough evaluation of existing approaches, we collected a novel dataset called CHILL, which systematically varies heart rate and lighting conditions. The dataset consists of recordings from 45 participants in four different scenarios. The video data was collected under two different lighting conditions (high and low) and normal and elevated heart rates. In addition, we selected two public datasets to conduct within- and cross-dataset evaluations of the rPPG methods. Our experimental results indicate that classical methods are not significantly impacted by low-light conditions. Meanwhile, some deep learning methods were found to be more robust to changes in lighting conditions but encountered challenges in estimating high heart rates. The cross-dataset evaluation revealed that the selected deep learning methods underperformed when influencing factors such as elevated heart rates and low lighting conditions were not present in the training set.

Publication Details

Journal
ArXiv.org
Published
2025-03-11
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Generalization of Video-Based Heart Rate Estimation Methods To Low Illumination and Elevated Heart Rates

ArXiv.org
Non-Invasive Vital Sign Monitoring
article

Generalization of Video-Based Heart Rate Estimation Methods To Low Illumination and Elevated Heart Rates

article en

Abstract

Heart rate is a physiological signal that provides information about an individual's health and affective state. Remote photoplethysmography (rPPG) allows the estimation of this signal from video recordings of a person's face. Classical rPPG methods make use of signal processing techniques, while recent rPPG methods utilize deep learning networks. Methods are typically evaluated on datasets collected in well-lit environments with participants at resting heart rates. However, little investigation has been done on how well these methods adapt to variations in illumination and heart rate. In this work, we systematically evaluate representative state-of-the-art methods for remote heart rate estimation. Specifically, we evaluate four classical methods and four deep learning-based rPPG estimation methods in terms of their generalization ability to changing scenarios, including low lighting conditions and elevated heart rates. For a thorough evaluation of existing approaches, we collected a novel dataset called CHILL, which systematically varies heart rate and lighting conditions. The dataset consists of recordings from 45 participants in four different scenarios. The video data was collected under two different lighting conditions (high and low) and normal and elevated heart rates. In addition, we selected two public datasets to conduct within- and cross-dataset evaluations of the rPPG methods. Our experimental results indicate that classical methods are not significantly impacted by low-light conditions. Meanwhile, some deep learning methods were found to be more robust to changes in lighting conditions but encountered challenges in estimating high heart rates. The cross-dataset evaluation revealed that the selected deep learning methods underperformed when influencing factors such as elevated heart rates and low lighting conditions were not present in the training set.

ArXiv.org
Good health and well-being
Openalex Percentile: Top 53%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.