BodySense: An Expandable and Wearable-Sized Wireless Evaluation Platform for Human Body Communication

Wearable, wirelessly connected sensors have become a common part of daily life and have the potential to play a pivotal role in shaping the future of personalized healthcare. A key challenge in this evolution is designing long-lasting and unobtrusive devices. These design requirements inherently demand smaller batteries, inevitably increasing the need for energy-sensitive wireless communication interfaces. Capacitive Human Body Communication (HBC) is a promising, power-efficient alternative to traditional RF-based communication, enabling point-to-multipoint data and energy exchange. However, as this concept relies on capacitive coupling to the surrounding area, it is naturally influenced by uncontrollable environmental factors, making testing with classical setups particularly challenging. This work presents a customizable, wearable-sized, wireless evaluation platform for capacitive HBC, designed to enable realistic evaluation of wearable-to-wearable applications. Comparative measurements of channel gains were conducted using classical grid-connected and wireless Data Acquisition (DAQ) across various transmission distances within the frequency range of 4 MHz to 64 MHz and revealed an average overestimation of 18.15 dB over all investigated distances in the classical setup.

Publication Details

Journal
ArXiv.org
Published
2025-02-07
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BodySense: An Expandable and Wearable-Sized Wireless Evaluation Platform for Human Body Communication

ArXiv.org
Wireless Body Area Networks
article

BodySense: An Expandable and Wearable-Sized Wireless Evaluation Platform for Human Body Communication

article en

Abstract

Wearable, wirelessly connected sensors have become a common part of daily life and have the potential to play a pivotal role in shaping the future of personalized healthcare. A key challenge in this evolution is designing long-lasting and unobtrusive devices. These design requirements inherently demand smaller batteries, inevitably increasing the need for energy-sensitive wireless communication interfaces. Capacitive Human Body Communication (HBC) is a promising, power-efficient alternative to traditional RF-based communication, enabling point-to-multipoint data and energy exchange. However, as this concept relies on capacitive coupling to the surrounding area, it is naturally influenced by uncontrollable environmental factors, making testing with classical setups particularly challenging. This work presents a customizable, wearable-sized, wireless evaluation platform for capacitive HBC, designed to enable realistic evaluation of wearable-to-wearable applications. Comparative measurements of channel gains were conducted using classical grid-connected and wireless Data Acquisition (DAQ) across various transmission distances within the frequency range of 4 MHz to 64 MHz and revealed an average overestimation of 18.15 dB over all investigated distances in the classical setup.

ArXiv.org
Affordable and clean energy
Openalex Percentile: Top 53%
Wireless Body Area Networks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

BodySense: An Expandable and Wearable-Sized Wireless Evaluation Platform for Human Body Communication · ArXiv.org (2025) | TGRS Research Map | TGRS