Pulmonary Tuberculosis Edge Diagnosis System Based on MindSpore Framework: Low-cost and High-precision Implementation with Ascend 310 Chip

Pulmonary Tuberculosis (PTB) remains a major challenge for global health, especially in areas with poor medical resources, where access to specialized medical knowledge and diagnostic tools is limited. This paper presents an auxiliary diagnosis system for pulmonary tuberculosis based on Huawei MindSpore framework and Ascend310 edge computing chip. Using MobileNetV3 architecture and Softmax cross entropy loss function with momentum optimizer. The system operates with FP16 hybrid accuracy on the Orange pie AIPro (Atlas 200 DK) edge device and performs well. In the test set containing 4148 chest images, the model accuracy reached 99.1\% (AUC = 0.99), and the equipment cost was controlled within \$150, providing affordable AI-assisted diagnosis scheme for primary care.

Publication Details

Journal
ArXiv.org
Published
2025-02-15
Primary Topic
History of Computing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulmonary Tuberculosis Edge Diagnosis System Based on MindSpore Framework: Low-cost and High-precision Implementation with Ascend 310 Chip

ArXiv.org
History of Computing Technologies
article

Pulmonary Tuberculosis Edge Diagnosis System Based on MindSpore Framework: Low-cost and High-precision Implementation with Ascend 310 Chip

article en

Abstract

Pulmonary Tuberculosis (PTB) remains a major challenge for global health, especially in areas with poor medical resources, where access to specialized medical knowledge and diagnostic tools is limited. This paper presents an auxiliary diagnosis system for pulmonary tuberculosis based on Huawei MindSpore framework and Ascend310 edge computing chip. Using MobileNetV3 architecture and Softmax cross entropy loss function with momentum optimizer. The system operates with FP16 hybrid accuracy on the Orange pie AIPro (Atlas 200 DK) edge device and performs well. In the test set containing 4148 chest images, the model accuracy reached 99.1\% (AUC = 0.99), and the equipment cost was controlled within \$150, providing affordable AI-assisted diagnosis scheme for primary care.

ArXiv.org
No poverty
Openalex Percentile: Top 45%
History of Computing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pulmonary Tuberculosis Edge Diagnosis System Based on MindSpore Framework: Low-cost and High-precision Implementation with Ascend 310 Chip · ArXiv.org (2025) | TGRS Research Map | TGRS