Rethinking Glaucoma Calibration: Voting-Based Binocular and Metadata Integration

Glaucoma is a major cause of irreversible blindness, with significant diagnostic subjectivity. This inherent uncertainty, combined with the overconfidence of models optimized solely for accuracy can lead to fatal issues such as overdiagnosis or missing critical diseases. To ensure clinical trust, model calibration is essential for reliable predictions, yet study in this field remains limited. Existing calibration study have overlooked glaucoma's systemic associations and high diagnostic subjectivity. To overcome these limitations, we propose V-ViT (Voting-based ViT), a framework that enhances calibration by integrating a patient's binocular information and metadata. Furthermore, to mitigate diagnostic subjectivity, V-ViT utilizes an iterative dropout-based Voting System to maximize calibration performance. The proposed framework achieved state-of-the-art performance across all metrics, including the primary calibration metrics. Our results demonstrate that V-ViT effectively resolves the issue of overconfidence in predictions in glaucoma diagnosis, providing highly reliable predictions for clinical use. Our source code is available at https://github.com/starforTJ/V-ViT.

Publication Details

Journal
ArXiv.org
Published
2025-03-24
Primary Topic
Australian History and Society
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rethinking Glaucoma Calibration: Voting-Based Binocular and Metadata Integration

ArXiv.org
Australian History and Society
article

Rethinking Glaucoma Calibration: Voting-Based Binocular and Metadata Integration

article en

Abstract

Glaucoma is a major cause of irreversible blindness, with significant diagnostic subjectivity. This inherent uncertainty, combined with the overconfidence of models optimized solely for accuracy can lead to fatal issues such as overdiagnosis or missing critical diseases. To ensure clinical trust, model calibration is essential for reliable predictions, yet study in this field remains limited. Existing calibration study have overlooked glaucoma's systemic associations and high diagnostic subjectivity. To overcome these limitations, we propose V-ViT (Voting-based ViT), a framework that enhances calibration by integrating a patient's binocular information and metadata. Furthermore, to mitigate diagnostic subjectivity, V-ViT utilizes an iterative dropout-based Voting System to maximize calibration performance. The proposed framework achieved state-of-the-art performance across all metrics, including the primary calibration metrics. Our results demonstrate that V-ViT effectively resolves the issue of overconfidence in predictions in glaucoma diagnosis, providing highly reliable predictions for clinical use. Our source code is available at https://github.com/starforTJ/V-ViT.

ArXiv.org
Peace, Justice and strong institutions
Openalex Percentile: Top 40%
Australian History and Society
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.