Lateral force microscopy calibration using an interferometric atomic force microscope

A new method is introduced for calibrating lateral force as measured by an atomic force microscope (AFM), making use of both an interferometric detector and an optical beam detector on the same instrument. The method may be implemented automatically and performed with minimal user input. The microscope has the capability to measure the probe tip height in situ, which allows for a complete lateral force calibration without changing the sample or probe. Two options for lateral force measurements are described wherein the two detectors are alternately used to measure normal and lateral forces, and methods for applying the calibration protocol for both alternatives are provided. The tip height measurement is validated by direct comparison with an electron micrograph and they are generally in agreement to within 1.4 microns. For most cantilevers tested, the complete lateral calibration method is consistent with the wedge calibration method to within the intrinsic uncertainty of the wedge method.

Publication Details

Journal
ArXiv.org
Published
2025-03-24
Primary Topic
Big Data and Digital Economy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lateral force microscopy calibration using an interferometric atomic force microscope

ArXiv.org
Big Data and Digital Economy
article

Lateral force microscopy calibration using an interferometric atomic force microscope

article en

Abstract

A new method is introduced for calibrating lateral force as measured by an atomic force microscope (AFM), making use of both an interferometric detector and an optical beam detector on the same instrument. The method may be implemented automatically and performed with minimal user input. The microscope has the capability to measure the probe tip height in situ, which allows for a complete lateral force calibration without changing the sample or probe. Two options for lateral force measurements are described wherein the two detectors are alternately used to measure normal and lateral forces, and methods for applying the calibration protocol for both alternatives are provided. The tip height measurement is validated by direct comparison with an electron micrograph and they are generally in agreement to within 1.4 microns. For most cantilevers tested, the complete lateral calibration method is consistent with the wedge calibration method to within the intrinsic uncertainty of the wedge method.

ArXiv.org
Affordable and clean energy
Openalex Percentile: Top 37%
Big Data and Digital Economy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.