Blind Source Separation in Biomedical Signals Using Variational Methods

This study introduces a novel unsupervised approach for separating overlapping heart and lung sounds using variational autoencoders (VAEs). In clinical settings, these sounds often interfere with each other, making manual separation difficult and error-prone. The proposed model learns to encode mixed signals into a structured latent space and reconstructs the individual components using a probabilistic decoder, all without requiring labeled data or prior knowledge of source characteristics. We apply this method to real recordings obtained from a clinical manikin using a digital stethoscope. Results demonstrate distinct latent clusters corresponding to heart and lung sources, as well as accurate reconstructions that preserve key spectral features of the original signals. The approach offers a robust and interpretable solution for blind source separation and has potential applications in portable diagnostic tools and intelligent stethoscope systems.

Publication Details

Journal
ArXiv.org
Published
2025-06-23
Primary Topic
Animal health and immunology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Blind Source Separation in Biomedical Signals Using Variational Methods

ArXiv.org
Animal health and immunology
article

Blind Source Separation in Biomedical Signals Using Variational Methods

article en

Abstract

This study introduces a novel unsupervised approach for separating overlapping heart and lung sounds using variational autoencoders (VAEs). In clinical settings, these sounds often interfere with each other, making manual separation difficult and error-prone. The proposed model learns to encode mixed signals into a structured latent space and reconstructs the individual components using a probabilistic decoder, all without requiring labeled data or prior knowledge of source characteristics. We apply this method to real recordings obtained from a clinical manikin using a digital stethoscope. Results demonstrate distinct latent clusters corresponding to heart and lung sources, as well as accurate reconstructions that preserve key spectral features of the original signals. The approach offers a robust and interpretable solution for blind source separation and has potential applications in portable diagnostic tools and intelligent stethoscope systems.

ArXiv.org
Openalex Percentile: Top 40%
Animal health and immunology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.