On-chip calibration of Microscale-Thermocouples for Precise Temperature Measurement

Precise temperature measurement at micro/nanoscale is crucial across various domains including physical sciences, chemical processes, industrial production, medical diagnosis, weather forecasting, electronics, and biology. Micro/nanoscale thermal mapping requires precise techniques such as thermocouples, resistance-based devices, infrared thermography, optical interferometry, Raman thermometry, and Time domain-thermoreflectance (TDTR) method. Each method has its advantages and limitations, emphasizing the importance of selecting the appropriate technique. Among these methods, micro-thin film thermocouples (TFTCs) offer a compelling solution due to their direct contact-based temperature measurements, minimal surface preparation requirements, lower cost, and robustness against environmental factors. Thermocouples work on the well-established Seebeck effect, where a voltage is generated proportional to the temperature difference between two points. However, at micro/nanoscale, the Seebeck coefficients of thermocouples differ from those in bulk materials, requiring experimental calibration for precise measurements. To address this, we introduce an on-chip characterization platform with a differential temperature measurement setup on a borosilicate glass substrate. This platform utilizes a microheater as a localized heat source to elevate the temperature at the hot junction of the TFTC while maintaining the cold junction at ambient conditions. Numerical simulations are employed to engineer both the microheater and TFTC junction for precise temperature control. The functionality of this platform is validated by fabricating TFTCs using standard fabrication processes and measuring the TFTC response to determine the differential Seebeck coefficient of a Platinum-Chromium TFTC Junction. The calculated sensitivity of Pt/Cr TFTCs using this calibration method is 19.23 +- 0.405 {\mu}V/C.

Publication Details

Journal
ArXiv.org
Published
2025-03-24
Primary Topic
Military Technology and Strategies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-chip calibration of Microscale-Thermocouples for Precise Temperature Measurement

ArXiv.org
Military Technology and Strategies
article

On-chip calibration of Microscale-Thermocouples for Precise Temperature Measurement

article en

Abstract

Precise temperature measurement at micro/nanoscale is crucial across various domains including physical sciences, chemical processes, industrial production, medical diagnosis, weather forecasting, electronics, and biology. Micro/nanoscale thermal mapping requires precise techniques such as thermocouples, resistance-based devices, infrared thermography, optical interferometry, Raman thermometry, and Time domain-thermoreflectance (TDTR) method. Each method has its advantages and limitations, emphasizing the importance of selecting the appropriate technique. Among these methods, micro-thin film thermocouples (TFTCs) offer a compelling solution due to their direct contact-based temperature measurements, minimal surface preparation requirements, lower cost, and robustness against environmental factors. Thermocouples work on the well-established Seebeck effect, where a voltage is generated proportional to the temperature difference between two points. However, at micro/nanoscale, the Seebeck coefficients of thermocouples differ from those in bulk materials, requiring experimental calibration for precise measurements. To address this, we introduce an on-chip characterization platform with a differential temperature measurement setup on a borosilicate glass substrate. This platform utilizes a microheater as a localized heat source to elevate the temperature at the hot junction of the TFTC while maintaining the cold junction at ambient conditions. Numerical simulations are employed to engineer both the microheater and TFTC junction for precise temperature control. The functionality of this platform is validated by fabricating TFTCs using standard fabrication processes and measuring the TFTC response to determine the differential Seebeck coefficient of a Platinum-Chromium TFTC Junction. The calculated sensitivity of Pt/Cr TFTCs using this calibration method is 19.23 +- 0.405 {\mu}V/C.

ArXiv.org
Openalex Percentile: Top 37%
Military Technology and Strategies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.