Analyzing the Impact of AC False Data Injection Attacks on Power System Operation

False Data Injection (FDI) attacks are a significant threat to modern power systems. Although numerous research studies have focused on FDI attacks on power systems, these studies have primarily concentrated on designing or detecting DC FDI attacks, with less attention given to the impact analysis of AC FDI attacks. AC FDI attacks are potentially more harmful as they can easily bypass bad data detection (BDD) algorithms. In this paper, we present a unified approach to investigate the impact of AC FDI attacks on power transmission lines using the PowerWorld simulator. We also investigate the impact of different FDI attack designs, including those optimally designed to evade BDD algorithms and compare them accordingly. Our findings demonstrate that in designing optimal AC FDI attacks, a trade-off between the residuals of state variables and the corresponding impacts of the proposed attack should be considered. This is because optimal attacks result in fewer changes in the attacked variable states and their estimated residuals compared to arbitrary AC FDI attacks. Moreover, the impacts of optimal AC FDI attacks can be less severe than those of arbitrary attacks. We implement and analyze the proposed approach on the IEEE 39-bus test system using PowerWorld simulator.

Publication Details

Journal
ArXiv.org
Published
2025-02-27
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analyzing the Impact of AC False Data Injection Attacks on Power System Operation

ArXiv.org
Smart Grid Security and Resilience
article

Analyzing the Impact of AC False Data Injection Attacks on Power System Operation

article en

Abstract

False Data Injection (FDI) attacks are a significant threat to modern power systems. Although numerous research studies have focused on FDI attacks on power systems, these studies have primarily concentrated on designing or detecting DC FDI attacks, with less attention given to the impact analysis of AC FDI attacks. AC FDI attacks are potentially more harmful as they can easily bypass bad data detection (BDD) algorithms. In this paper, we present a unified approach to investigate the impact of AC FDI attacks on power transmission lines using the PowerWorld simulator. We also investigate the impact of different FDI attack designs, including those optimally designed to evade BDD algorithms and compare them accordingly. Our findings demonstrate that in designing optimal AC FDI attacks, a trade-off between the residuals of state variables and the corresponding impacts of the proposed attack should be considered. This is because optimal attacks result in fewer changes in the attacked variable states and their estimated residuals compared to arbitrary AC FDI attacks. Moreover, the impacts of optimal AC FDI attacks can be less severe than those of arbitrary attacks. We implement and analyze the proposed approach on the IEEE 39-bus test system using PowerWorld simulator.

ArXiv.org
Peace, Justice and strong institutions
Openalex Percentile: Top 46%
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.