Towards integrated sensors for optimized OCT with undetected photons

The development of practical sensors for optical coherence tomography (OCT) with undetected photons requires miniaturization via integration. To be practical, these sensors must exhibit a large spectral bandwidth and a high brightness, which are linked to a high axial resolution and a sufficient signal to noise ratio, respectively. Here, we combine these requirements in a scheme for OCT-measurements with undetected photons based on nonlinear Ti:LiNbO$_3$ waveguides. We investigate the performance benchmarks of the commonly used SU(1,1) scheme in comparison to an induced coherence scheme and find that the latter is actually better suited when implementing measurements with undetected photons in integrated systems. In both schemes, we perform pump gain optimization and OCT measurements with undetected photons with an axial resolution as low as 28 $\mathrmμ$m.

Publication Details

Journal
ArXiv.org
Published
2025-08-07
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards integrated sensors for optimized OCT with undetected photons

ArXiv.org
Optical Coherence Tomography Applications
article

Towards integrated sensors for optimized OCT with undetected photons

article en

Abstract

The development of practical sensors for optical coherence tomography (OCT) with undetected photons requires miniaturization via integration. To be practical, these sensors must exhibit a large spectral bandwidth and a high brightness, which are linked to a high axial resolution and a sufficient signal to noise ratio, respectively. Here, we combine these requirements in a scheme for OCT-measurements with undetected photons based on nonlinear Ti:LiNbO$_3$ waveguides. We investigate the performance benchmarks of the commonly used SU(1,1) scheme in comparison to an induced coherence scheme and find that the latter is actually better suited when implementing measurements with undetected photons in integrated systems. In both schemes, we perform pump gain optimization and OCT measurements with undetected photons with an axial resolution as low as 28 $\mathrmμ$m.

ArXiv.org
Openalex Percentile: Top 53%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Towards integrated sensors for optimized OCT with undetected photons · ArXiv.org (2025) | TGRS Research Map | TGRS