Narrow Inhomogeneous Distribution and Charge State Stabilization of Lead-Vacancy Centers in Diamond

Lead-vacancy (PbV) centers in diamond with a large ground state splitting are expected to be a building block of quantum network nodes. Due to the heaviness of the Pb atom, it is challenging to fabricate high-quality PbV centers with a narrow inhomogeneous distribution and stable charge state. In this study, for the formation of the PbV centers, high temperature anneal up to 2300{\deg}C is performed after Pb ion implantation. At a lower temperature of 1800{\deg}C, the PbV centers show a large inhomogeneous distribution and spectral diffusion, while higher temperatures of 2200-2300{\deg}C leads to narrow inhomogeneous distributions with standard deviations of ~5 GHz. The charge state transition of the PbV centers formed at 2200{\deg}C occurs by capturing photo-carriers generated from surrounding defects under 532 nm laser irradiation. Finally, multiple stable PbV centers with nearly identical photon frequencies are obtained, which is essential for applications in quantum information processing.

Publication Details

Journal
ArXiv.org
Published
2025-05-01
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Narrow Inhomogeneous Distribution and Charge State Stabilization of Lead-Vacancy Centers in Diamond

ArXiv.org
Diamond and Carbon-based Materials Research
article

Narrow Inhomogeneous Distribution and Charge State Stabilization of Lead-Vacancy Centers in Diamond

article en

Abstract

Lead-vacancy (PbV) centers in diamond with a large ground state splitting are expected to be a building block of quantum network nodes. Due to the heaviness of the Pb atom, it is challenging to fabricate high-quality PbV centers with a narrow inhomogeneous distribution and stable charge state. In this study, for the formation of the PbV centers, high temperature anneal up to 2300{\deg}C is performed after Pb ion implantation. At a lower temperature of 1800{\deg}C, the PbV centers show a large inhomogeneous distribution and spectral diffusion, while higher temperatures of 2200-2300{\deg}C leads to narrow inhomogeneous distributions with standard deviations of ~5 GHz. The charge state transition of the PbV centers formed at 2200{\deg}C occurs by capturing photo-carriers generated from surrounding defects under 532 nm laser irradiation. Finally, multiple stable PbV centers with nearly identical photon frequencies are obtained, which is essential for applications in quantum information processing.

ArXiv.org
Ministry of Education, Culture, Sports, Science and Technology, Japan Society for the Promotion of Science, Moonshot Research and Development Program
Sustainable cities and communities
Openalex Percentile: Top 60%
Diamond and Carbon-based Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.