Effect of micromagnetorotation on a micropolar magnetohydrodynamic blood flow in a 3D stenosed artery

This study presents a numerical investigation of a 3D micropolar magnetohydrodynamic (MHD) blood flow through stenosis, with and without the effects of micromagnetorotation (MMR). MMR refers to the magnetic torque caused by the misalignment of the magnetization of magnetic particles in the fluid with the magnetic field, which affects the internal rotation (microrotation) of these particles. Blood can be modeled as a micropolar fluid with magnetic particles due to the magnetization of erythrocytes. In this manner, this study analyzes important flow features, i.e., streamlines, vorticity, velocity, and microrotation, under varying stenosis (50%, 80%), hematocrit levels (25%, 45%), and magnetic fields (1T, 3T, 8T), using two newly developed transient OpenFOAM solvers epotMicropolarFoam and epotMMRFoam. Results indicate that micropolar effects become more pronounced at severe stenosis due to the significant reduction in artery size. Furthermore, when MMR is disregarded (i.e., when blood is modeled as a classical MHD micropolar fluid without magnetic particles), the magnetic field does not significantly alter blood flow, regardless of its intensity, due to the minimal impact of the Lorentz force on blood. Conversely, MMR substantially affects blood flow, particularly at higher hematocrit levels and severe stenoses, leading to reductions of up to 30% in velocity and vorticity and up to 99.9% in microrotation. Simultaneously, any vortices or disturbances are dampened. These findings underscore the critical role of MMR (which was ignored so far) in altering flow behavior in stenosed arteries, suggesting that it should be considered in future MHD micropolar blood flow studies.

Publication Details

Journal
arXiv (Cornell University)
Published
2025-04-18
Primary Topic
Nanofluid Flow and Heat Transfer
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of micromagnetorotation on a micropolar magnetohydrodynamic blood flow in a 3D stenosed artery

arXiv (Cornell University)
Nanofluid Flow and Heat Transfer
article

Effect of micromagnetorotation on a micropolar magnetohydrodynamic blood flow in a 3D stenosed artery

article en

Abstract

This study presents a numerical investigation of a 3D micropolar magnetohydrodynamic (MHD) blood flow through stenosis, with and without the effects of micromagnetorotation (MMR). MMR refers to the magnetic torque caused by the misalignment of the magnetization of magnetic particles in the fluid with the magnetic field, which affects the internal rotation (microrotation) of these particles. Blood can be modeled as a micropolar fluid with magnetic particles due to the magnetization of erythrocytes. In this manner, this study analyzes important flow features, i.e., streamlines, vorticity, velocity, and microrotation, under varying stenosis (50%, 80%), hematocrit levels (25%, 45%), and magnetic fields (1T, 3T, 8T), using two newly developed transient OpenFOAM solvers epotMicropolarFoam and epotMMRFoam. Results indicate that micropolar effects become more pronounced at severe stenosis due to the significant reduction in artery size. Furthermore, when MMR is disregarded (i.e., when blood is modeled as a classical MHD micropolar fluid without magnetic particles), the magnetic field does not significantly alter blood flow, regardless of its intensity, due to the minimal impact of the Lorentz force on blood. Conversely, MMR substantially affects blood flow, particularly at higher hematocrit levels and severe stenoses, leading to reductions of up to 30% in velocity and vorticity and up to 99.9% in microrotation. Simultaneously, any vortices or disturbances are dampened. These findings underscore the critical role of MMR (which was ignored so far) in altering flow behavior in stenosed arteries, suggesting that it should be considered in future MHD micropolar blood flow studies.

arXiv (Cornell University)
Openalex Percentile: Top 53%
Nanofluid Flow and Heat Transfer
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.