A Liquid-Nitrogen-Cooled Ca+ Ion Optical Clock with a Systematic Uncertainty of 4.4E-19

We report a single-ion optical clock based on the 4S_1/2-3D_5/2 transition of the 40Ca+ ion, operated in a liquid nitrogen cryogenic environment,achieving a total systematic uncertainty of 4.4E-19. We employ a refined temperature evaluation scheme to reduce the frequency uncertainty due to blackbody radiation (BBR), and the 3D sideband cooling has been implemented to minimize the second-order Doppler shift. We have precisely determined the average Zeeman coefficient of the 40Ca+ clock transition to be 14.345(40) Hz/mT^2, thereby significantly reducing the quadratic Zeeman shift uncertainty. Moreover, the cryogenic environment enables the lowest reported heating rate due to ambient electric field noise in trapped-ion optical clocks.

Publication Details

Journal
ArXiv.org
Published
2025-06-20
Primary Topic
Advanced Frequency and Time Standards
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Liquid-Nitrogen-Cooled Ca+ Ion Optical Clock with a Systematic Uncertainty of 4.4E-19

ArXiv.org
Advanced Frequency and Time Standards
article

A Liquid-Nitrogen-Cooled Ca+ Ion Optical Clock with a Systematic Uncertainty of 4.4E-19

article en

Abstract

We report a single-ion optical clock based on the 4S_1/2-3D_5/2 transition of the 40Ca+ ion, operated in a liquid nitrogen cryogenic environment,achieving a total systematic uncertainty of 4.4E-19. We employ a refined temperature evaluation scheme to reduce the frequency uncertainty due to blackbody radiation (BBR), and the 3D sideband cooling has been implemented to minimize the second-order Doppler shift. We have precisely determined the average Zeeman coefficient of the 40Ca+ clock transition to be 14.345(40) Hz/mT^2, thereby significantly reducing the quadratic Zeeman shift uncertainty. Moreover, the cryogenic environment enables the lowest reported heating rate due to ambient electric field noise in trapped-ion optical clocks.

ArXiv.org
Openalex Percentile: Top 53%
Advanced Frequency and Time Standards
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Liquid-Nitrogen-Cooled Ca+ Ion Optical Clock with a Systematic Uncertainty of 4.4E-19 · ArXiv.org (2025) | TGRS Research Map | TGRS