Irradiation Study Using QA Test Pieces of ATLAS18 ITk Strip Sensors with 80MeV Protons

The ATLAS experiment is planning a complete replacement of its inner detector(ID) with a new all-silicon inner tracker (ITk) for the ATLAS Inner Tracker Phase-2 upgrade. The ATLAS18 silicon strip sensors are designed to operate up to the integrated luminosity of 4000 fb$^{-1}$, which corresponds to the maximum fluence of $1.6 \times 10^{15} \, \text n_{\text{eq}} / \text{cm}^2$ (including safety factor). To enhance the quality assurance (QA) program to monitor the key properties of the sensors, the strip sensor community is considering to include China Spallation Neutron Source (CSNS) as a proton irradiation site and Institute of High Energy Physics (IHEP) as a QA test site. A total of 18 ATLAS18 ITk QA test pieces were irradiated with $6.0 \times 10^{14}$, $1.6 \times 10^{15}$, and $2.6 \times 10^{15} \, \text n_{\text{eq}} / \text{cm}^2$ protons at CSNS, and measured at IHEP, including IV (leakage current-voltage), CV (capacitance-voltage) and CCE (charge collection efficiency) measurements. The upgraded irradiation setup at CSNS and measurement setup at IHEP are shown in this paper. Irradiated samples were exchanged between IHEP, Ljubljana and Birmingham to cross-check CCE measurements.

Publication Details

Journal
ArXiv.org
Published
2025-03-25
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Irradiation Study Using QA Test Pieces of ATLAS18 ITk Strip Sensors with 80MeV Protons

ArXiv.org
Particle Detector Development and Performance
article

Irradiation Study Using QA Test Pieces of ATLAS18 ITk Strip Sensors with 80MeV Protons

article en

Abstract

The ATLAS experiment is planning a complete replacement of its inner detector(ID) with a new all-silicon inner tracker (ITk) for the ATLAS Inner Tracker Phase-2 upgrade. The ATLAS18 silicon strip sensors are designed to operate up to the integrated luminosity of 4000 fb$^{-1}$, which corresponds to the maximum fluence of $1.6 \times 10^{15} \, \text n_{\text{eq}} / \text{cm}^2$ (including safety factor). To enhance the quality assurance (QA) program to monitor the key properties of the sensors, the strip sensor community is considering to include China Spallation Neutron Source (CSNS) as a proton irradiation site and Institute of High Energy Physics (IHEP) as a QA test site. A total of 18 ATLAS18 ITk QA test pieces were irradiated with $6.0 \times 10^{14}$, $1.6 \times 10^{15}$, and $2.6 \times 10^{15} \, \text n_{\text{eq}} / \text{cm}^2$ protons at CSNS, and measured at IHEP, including IV (leakage current-voltage), CV (capacitance-voltage) and CCE (charge collection efficiency) measurements. The upgraded irradiation setup at CSNS and measurement setup at IHEP are shown in this paper. Irradiated samples were exchanged between IHEP, Ljubljana and Birmingham to cross-check CCE measurements.

ArXiv.org
Affordable and clean energy
Openalex Percentile: Top 76%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Irradiation Study Using QA Test Pieces of ATLAS18 ITk Strip Sensors with 80MeV Protons · ArXiv.org (2025) | TGRS Research Map | TGRS