Impulsive pattern recognition of a myoelectric hand via Dynamic Time Warping

Although myoelectric prosthetic hands provide amputees with intuitive control, their reliance on many EMG sensors limits accessibility and makes them complex and expensive. To address this problem, this work presents a different perspective that makes use of a single EMG sensor and brief impulse signals in conjunction with Dynamic Time Warping (DTW) for accurate pattern detection. Conventional techniques rely on real-time data from multiple sensors, which can be costly and bulky. The method presents high accuracy while lowering hardware complexity and expense. A DTW-based system that reliably identifies muscle activation patterns from short EMG signals was created and tested. Results show that this single-sensor approach obtained an accuracy rate of 92%, which is similar to that of conventional multi-sensor systems. This research provides a more straightforward and economical approach that can be used to obtain enhanced myoelectric control. These findings provide a different perspective on more easily accessible and user-friendly prosthetic devices, which will be especially helpful in disaster-affected areas where quick deployment is essential. Future improvements would investigate this system's dependability over time and wider implementations in real situations, to take prosthetic technology one step further.

Publication Details

Journal
ArXiv.org
Published
2025-04-21
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impulsive pattern recognition of a myoelectric hand via Dynamic Time Warping

ArXiv.org
Muscle activation and electromyography studies
article

Impulsive pattern recognition of a myoelectric hand via Dynamic Time Warping

article en

Abstract

Although myoelectric prosthetic hands provide amputees with intuitive control, their reliance on many EMG sensors limits accessibility and makes them complex and expensive. To address this problem, this work presents a different perspective that makes use of a single EMG sensor and brief impulse signals in conjunction with Dynamic Time Warping (DTW) for accurate pattern detection. Conventional techniques rely on real-time data from multiple sensors, which can be costly and bulky. The method presents high accuracy while lowering hardware complexity and expense. A DTW-based system that reliably identifies muscle activation patterns from short EMG signals was created and tested. Results show that this single-sensor approach obtained an accuracy rate of 92%, which is similar to that of conventional multi-sensor systems. This research provides a more straightforward and economical approach that can be used to obtain enhanced myoelectric control. These findings provide a different perspective on more easily accessible and user-friendly prosthetic devices, which will be especially helpful in disaster-affected areas where quick deployment is essential. Future improvements would investigate this system's dependability over time and wider implementations in real situations, to take prosthetic technology one step further.

ArXiv.org
Climate action
Openalex Percentile: Top 53%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impulsive pattern recognition of a myoelectric hand via Dynamic Time Warping · ArXiv.org (2025) | TGRS Research Map | TGRS