International Comparison Results of Personal Dose Equivalent Hp(0.07) and Hp(3) in Beta Radiation

To establish the national primary standard for beta radiation tissue absorbed dose and to achieve international equivalence, the National Institute of Metrology (NIM) of China participated in the BIPM KCDB: EURAMET.RI(I)-S16 comparison that organized by EURAMET (European Association of National Metrology Institutes) and coordinated by the Physikalisch-Technische Bundesanstalt (PTB) in 2019. The circulation of the chamber and of the electronic measurement system will be effected in a star pattern, with both devices being sent back by every five participants to the pilot laboratory for testing. 16 institutes from 16 different countries will calibrate the comparison device according to their quality system in beta reference fields of the radionuclides 147Pm, 85Kr, 90Sr/90Y and 106Ru/106Rh. NIM calibrated the transfer ionization chambers using its beta radiation tissue absorbed dose primary standard, determining the calibration factors for Hp(0.07) at incident angles of 0°, 45°, and 60° in the radiation field of 85Kr and 90Sr/90Y sources, as well as the calibration factors for Hp(3) at various angles for the 90Sr/90Y source. The calibration factors obtained in this work were compared with the reference values provided by EURAMET. The relative deviations of the calibration factors for Hp(0.07) at incident angles of 0°, 45°, and 60° from the 90Sr/90Y and 85Kr sources compared to the reference values are better than ±0.8%; The relative deviations of the calibration factors for Hp(3) at incident angles of 0°, 45°, and 60° from the 90Sr/90Y source compared to the reference values are better than ±0.9%. The relative deviations for the nine results are better than ±1%. These results were incorporated into the International Bureau of Weights and Measures (BIPM) Key Comparison Database (KCDB), achieving international mutual recognition for the personal dose equivalents Hp(0.07) and Hp(3) in beta radiation.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.7538/yzk.2023.youxian.0819
Primary Topic
Radioactive Decay and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

International Comparison Results of Personal Dose Equivalent Hp(0.07) and Hp(3) in Beta Radiation

SHILAP Revista de lepidopterología
Radioactive Decay and Measurement Techniques
article

International Comparison Results of Personal Dose Equivalent Hp(0.07) and Hp(3) in Beta Radiation

article en

Abstract

To establish the national primary standard for beta radiation tissue absorbed dose and to achieve international equivalence, the National Institute of Metrology (NIM) of China participated in the BIPM KCDB: EURAMET.RI(I)-S16 comparison that organized by EURAMET (European Association of National Metrology Institutes) and coordinated by the Physikalisch-Technische Bundesanstalt (PTB) in 2019. The circulation of the chamber and of the electronic measurement system will be effected in a star pattern, with both devices being sent back by every five participants to the pilot laboratory for testing. 16 institutes from 16 different countries will calibrate the comparison device according to their quality system in beta reference fields of the radionuclides 147Pm, 85Kr, 90Sr/90Y and 106Ru/106Rh. NIM calibrated the transfer ionization chambers using its beta radiation tissue absorbed dose primary standard, determining the calibration factors for Hp(0.07) at incident angles of 0°, 45°, and 60° in the radiation field of 85Kr and 90Sr/90Y sources, as well as the calibration factors for Hp(3) at various angles for the 90Sr/90Y source. The calibration factors obtained in this work were compared with the reference values provided by EURAMET. The relative deviations of the calibration factors for Hp(0.07) at incident angles of 0°, 45°, and 60° from the 90Sr/90Y and 85Kr sources compared to the reference values are better than ±0.8%; The relative deviations of the calibration factors for Hp(3) at incident angles of 0°, 45°, and 60° from the 90Sr/90Y source compared to the reference values are better than ±0.9%. The relative deviations for the nine results are better than ±1%. These results were incorporated into the International Bureau of Weights and Measures (BIPM) Key Comparison Database (KCDB), achieving international mutual recognition for the personal dose equivalents Hp(0.07) and Hp(3) in beta radiation.

SHILAP Revista de lepidopterología
Partnerships for the goals
Openalex Percentile: Top 54%
Radioactive Decay and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

International Comparison Results of Personal Dose Equivalent Hp(0.07) and Hp(3) in Beta Radiation · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS