Development and Application of a Method for Pollution Level Analysis of 16 Phthalate Plasticizers in Pre-prepared Dishes

An efficient and rapid gas chromatography-tandem mass spectrometry (GC-MS/MS) method for the simultaneous determination of 16 phthalate plasticizers was established and applied to analyze the contamination levels of these phthalates in commercially available pre-prepared dishes. The results showed that a good linearity (R2 > 0.998) was obtained for all analytes in the concentration range of 0.02–2.00 mg/L, and the limit of detection (LOD) of the method ranged from 0.22 to 5.40 μg/kg. Recoveries at three spiked levels ranged from 79.6% to 117.2% with relative standard deviation (RSD) between 0.6% and 3.7%. In 100 samples, the detection rates of dimethyl phthalate (DMP), dibutyl phthalate (DBP) and bis(2-ethylhexyl) phthalate (DEHP) were 83.0%, 91.0% and 94.0% at concentrations of up to 334.7, 1 960.8 and 1 603.3 μg/kg, respectively. Among these samples, two were found to exceed the standard limits for DBP and DEHP, respectively. The proposed method was characterized by simple pretreatment, low blank control, good recovery, rapid analysis speed and high accuracy. This study provides methodological and data support for food safety risk assessment and supervision in the pre-prepared dish industry.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
DOI
https://doi.org/10.7506/spkx1002-6630-20241028-193
Primary Topic
Breast Lesions and Carcinomas
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Application of a Method for Pollution Level Analysis of 16 Phthalate Plasticizers in Pre-prepared Dishes

SHILAP Revista de lepidopterología
Breast Lesions and Carcinomas
article

Development and Application of a Method for Pollution Level Analysis of 16 Phthalate Plasticizers in Pre-prepared Dishes

article en

Abstract

An efficient and rapid gas chromatography-tandem mass spectrometry (GC-MS/MS) method for the simultaneous determination of 16 phthalate plasticizers was established and applied to analyze the contamination levels of these phthalates in commercially available pre-prepared dishes. The results showed that a good linearity (R2 > 0.998) was obtained for all analytes in the concentration range of 0.02–2.00 mg/L, and the limit of detection (LOD) of the method ranged from 0.22 to 5.40 μg/kg. Recoveries at three spiked levels ranged from 79.6% to 117.2% with relative standard deviation (RSD) between 0.6% and 3.7%. In 100 samples, the detection rates of dimethyl phthalate (DMP), dibutyl phthalate (DBP) and bis(2-ethylhexyl) phthalate (DEHP) were 83.0%, 91.0% and 94.0% at concentrations of up to 334.7, 1 960.8 and 1 603.3 μg/kg, respectively. Among these samples, two were found to exceed the standard limits for DBP and DEHP, respectively. The proposed method was characterized by simple pretreatment, low blank control, good recovery, rapid analysis speed and high accuracy. This study provides methodological and data support for food safety risk assessment and supervision in the pre-prepared dish industry.

SHILAP Revista de lepidopterología
Guangzhou Center for Disease Control and Prevention (CN)
Openalex Percentile: Top 38%
Breast Lesions and Carcinomas
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.