Semi-supervised mold differentiation using typical laboratory results as label data

This study applies semi-supervised learning to automate the differentiation of mold colonies, thereby reducing the time and cost associated with air quality assessments. EfficientNet V2 and Normalization-Free Net (NfNet) were trained on a dataset of mold colony images, created in a semi-supervised way. NfNet demonstrated superior performance, particularly on non-padded images, with explainable AI techniques enhancing interpretability. The models exhibited generalization capabilities to environmental samples, indicating the potential for automating mold identification and streamlining air quality monitoring, thereby reducing manual effort and costs. Future work will focus on refining species handling and integrating the system into laboratory workflows.

Institutions

Publication Details

Journal
Opus-HSO (Offenburg University of Applied Sciences)
Published
2024-10-15
DOI
https://doi.org/10.60643/urai.v2024p31
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Semi-supervised mold differentiation using typical laboratory results as label data

Opus-HSO (Offenburg University of Applied Sciences)
Indoor Air Quality and Microbial Exposure
article

Semi-supervised mold differentiation using typical laboratory results as label data

article en

Abstract

This study applies semi-supervised learning to automate the differentiation of mold colonies, thereby reducing the time and cost associated with air quality assessments. EfficientNet V2 and Normalization-Free Net (NfNet) were trained on a dataset of mold colony images, created in a semi-supervised way. NfNet demonstrated superior performance, particularly on non-padded images, with explainable AI techniques enhancing interpretability. The models exhibited generalization capabilities to environmental samples, indicating the potential for automating mold identification and streamlining air quality monitoring, thereby reducing manual effort and costs. Future work will focus on refining species handling and integrating the system into laboratory workflows.

Opus-HSO (Offenburg University of Applied Sciences)
BioTeSys (Germany) (DE), Offenburg University of Applied Sciences (DE)
Life in Land
Openalex Percentile: Top 49%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.