RP-HPLC Method Development and Validation of Dissolution Method for Anticoagulant Dosage Form

Anticoagulants are a class of dosage forms employed in the management of thrombotic conditions, which prolong the clotting duration. This research aims to quantify Edoxaban in solid oral dosage forms. A dissolution method for Edoxaban tablets has been developed, employing USP Apparatus II (Paddle) at a speed of 50 rpm with 900 ml of phosphate buffer (pH 6.0) as the medium at a temperature of 37°C. Additionally, a reversed-phase liquid chromatographic method was established for the simultaneous quantification of Edoxaban using a C18 column, which utilizes isocratic elution with acetonitrile and Triethylamine buffer (pH 5.5) at a flow rate of 1 mL/min. The retention time was approximately 4 minutes, and quantification was performed at its λmax (290 nm).Validation data were collected, demonstrating that the dissolution methodology is accurate, precise, linear, and robust for the Edoxaban immediate release tablet. Therefore, the proposed RP-HPLC method is suitable for routine quality control analysis for release determination.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-07-30
DOI
https://doi.org/10.5281/zenodo.16610313
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RP-HPLC Method Development and Validation of Dissolution Method for Anticoagulant Dosage Form

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

RP-HPLC Method Development and Validation of Dissolution Method for Anticoagulant Dosage Form

article en

Abstract

Anticoagulants are a class of dosage forms employed in the management of thrombotic conditions, which prolong the clotting duration. This research aims to quantify Edoxaban in solid oral dosage forms. A dissolution method for Edoxaban tablets has been developed, employing USP Apparatus II (Paddle) at a speed of 50 rpm with 900 ml of phosphate buffer (pH 6.0) as the medium at a temperature of 37°C. Additionally, a reversed-phase liquid chromatographic method was established for the simultaneous quantification of Edoxaban using a C18 column, which utilizes isocratic elution with acetonitrile and Triethylamine buffer (pH 5.5) at a flow rate of 1 mL/min. The retention time was approximately 4 minutes, and quantification was performed at its λmax (290 nm).Validation data were collected, demonstrating that the dissolution methodology is accurate, precise, linear, and robust for the Edoxaban immediate release tablet. Therefore, the proposed RP-HPLC method is suitable for routine quality control analysis for release determination.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 51%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

RP-HPLC Method Development and Validation of Dissolution Method for Anticoagulant Dosage Form · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS