ANALYSIS OF BUILDING WITH AND WITHOUT DAMPERS USING ETABS SOFTWARE

This project investigates the seismic behaviour of symmetrical and unsymmetrical G+26 buildings with and without Fluid Viscous Dampers (FVD) using ETABS 2022 software. The main objective is to evaluate the impact of FVDs on reducing seismic response, considering various damping device positions, shapes, and building heights. The study involves nonlinear time-history analysis using Electro data and seismic evaluations based on the equivalent static and response spectrum methods. The building is analysed for seismic Zone IV, medium soil conditions (Type II) as per IS 1893-2016. The study examines how structures, including multi-storey buildings, respond to earthquake vibrations. It highlights the importance of damping devices, like Fluid Viscous Dampers, in controlling seismic energy and reducing structural damage by controlling lateral displacements, shear forces, and bending moments. The analysis compares buildings with and without FVDs, considering factors such as story drift, shear force, and moments, and evaluates the effects of different soil conditions (high, medium, and loose). Results indicate that Fluid Viscous Dampers significantly improve the seismic performance of buildings, particularly in reducing story drifts, base shear.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-05-15
DOI
https://doi.org/10.5281/zenodo.15675302
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALYSIS OF BUILDING WITH AND WITHOUT DAMPERS USING ETABS SOFTWARE

Zenodo (CERN European Organization for Nuclear Research)
Seismic Performance and Analysis
article

ANALYSIS OF BUILDING WITH AND WITHOUT DAMPERS USING ETABS SOFTWARE

article en

Abstract

This project investigates the seismic behaviour of symmetrical and unsymmetrical G+26 buildings with and without Fluid Viscous Dampers (FVD) using ETABS 2022 software. The main objective is to evaluate the impact of FVDs on reducing seismic response, considering various damping device positions, shapes, and building heights. The study involves nonlinear time-history analysis using Electro data and seismic evaluations based on the equivalent static and response spectrum methods. The building is analysed for seismic Zone IV, medium soil conditions (Type II) as per IS 1893-2016. The study examines how structures, including multi-storey buildings, respond to earthquake vibrations. It highlights the importance of damping devices, like Fluid Viscous Dampers, in controlling seismic energy and reducing structural damage by controlling lateral displacements, shear forces, and bending moments. The analysis compares buildings with and without FVDs, considering factors such as story drift, shear force, and moments, and evaluates the effects of different soil conditions (high, medium, and loose). Results indicate that Fluid Viscous Dampers significantly improve the seismic performance of buildings, particularly in reducing story drifts, base shear.

Zenodo (CERN European Organization for Nuclear Research)
Government of Maharashtra (IN), Government of India (IN)
Sustainable cities and communities
Openalex Percentile: Top 53%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.