An in-vitro study to evaluate the accuracy of master casts obtained from different transfer impression techniques for a multi-unit implant restoration using two different impression materials evaluated by a 3-D optical scanner.

Abstract Background: The precise transfer of implant positions from the oral cavity to the working cast is critical for the passive fit of implant-supported prostheses. This study aimed to evaluate and compare the accuracy of master casts obtained through various impression techniques using two elastomeric materials—Polyvinyl Siloxane (PVS) and Polyether (PE)—assessed using a 3D optical scanning system (DWOS). Materials and Methods: An edentulous maxillary reference model with four internal connection implants was used. Forty impressions were made using custom trays and categorized into eight groups (n=5 each) based on impression technique (closed/open tray), coping modification (non-modified, sandblasted, or splinted), and impression material (PVS or PE). Master casts were fabricated from each impression, and positional accuracy of implant analogues was evaluated using a DWOS 3D scanner by measuring horizontal distances between implants 2–3 and 1–4. Statistical analysis was performed using one-way ANOVA. Results: The mean reference distances between implants 2–3 and 1–4 were 1.308" and 2.748", respectively. Although variations were observed across different groups, the differences in accuracy were not statistically significant. Splinted copings exhibited the highest accuracy, followed by sandblasted and non-modified copings. Polyether impressions showed slightly better agreement with the reference model, but the difference was not statistically significant. Conclusion: Within the limitations of this in vitro study, both PVS and PE impression materials yielded clinically acceptable accuracy in transferring implant positions. Non-splinted, non-modified impression copings provided comparable results, offering a simpler and more time-efficient approach. Further clinical studies are necessary to validate these findings under intraoral conditions.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-05-31
DOI
https://doi.org/10.5281/zenodo.15557572
Primary Topic
Academic integrity and plagiarism
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An in-vitro study to evaluate the accuracy of master casts obtained from different transfer impression techniques for a multi-unit implant restoration using two different impression materials evaluated by a 3-D optical scanner.

Zenodo (CERN European Organization for Nuclear Research)
Academic integrity and plagiarism
article

An in-vitro study to evaluate the accuracy of master casts obtained from different transfer impression techniques for a multi-unit implant restoration using two different impression materials evaluated by a 3-D optical scanner.

article en

Abstract

Abstract Background: The precise transfer of implant positions from the oral cavity to the working cast is critical for the passive fit of implant-supported prostheses. This study aimed to evaluate and compare the accuracy of master casts obtained through various impression techniques using two elastomeric materials—Polyvinyl Siloxane (PVS) and Polyether (PE)—assessed using a 3D optical scanning system (DWOS). Materials and Methods: An edentulous maxillary reference model with four internal connection implants was used. Forty impressions were made using custom trays and categorized into eight groups (n=5 each) based on impression technique (closed/open tray), coping modification (non-modified, sandblasted, or splinted), and impression material (PVS or PE). Master casts were fabricated from each impression, and positional accuracy of implant analogues was evaluated using a DWOS 3D scanner by measuring horizontal distances between implants 2–3 and 1–4. Statistical analysis was performed using one-way ANOVA. Results: The mean reference distances between implants 2–3 and 1–4 were 1.308" and 2.748", respectively. Although variations were observed across different groups, the differences in accuracy were not statistically significant. Splinted copings exhibited the highest accuracy, followed by sandblasted and non-modified copings. Polyether impressions showed slightly better agreement with the reference model, but the difference was not statistically significant. Conclusion: Within the limitations of this in vitro study, both PVS and PE impression materials yielded clinically acceptable accuracy in transferring implant positions. Non-splinted, non-modified impression copings provided comparable results, offering a simpler and more time-efficient approach. Further clinical studies are necessary to validate these findings under intraoral conditions.

Zenodo (CERN European Organization for Nuclear Research)
MNR Dental College and Hospital (IN), Govt. Dental College & Hospital (IN)
Sustainable cities and communities
Openalex Percentile: Top 48%
Academic integrity and plagiarism
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.