To Development and Validation RP-HPLC Method for Tinidazole in Bulk and Pharmaceutical Formulation.

A simple, precise, accurate, and robust Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) method was developed and validated for the quantitative estimation of Tinidazole in bulk and pharmaceutical dosage forms. Chromatographic separation was achieved using a mobile phase of Acetonitrile and Water (90:10 v/v), with the detection wavelength set at 270 nm. The method demonstrated excellent linearity in the concentration range of 5–30 µg/ml, with a correlation coefficient (r²) of 0.9996. The Limit of Detection (LOD) and Limit of Quantitation (LOQ) were found to be 2.5070 µg/ml and 7.5912 µg/ml respectively. Validation parameters such as system suitability, specificity, accuracy, precision (intra-day and inter-day), robustness, and sensitivity were conducted in accordance with ICH guidelines, confirming the reliability and reproducibility of the method. Recovery studies showed results within the acceptable range, indicating no interference from excipients. The proposed method is suitable for routine analysis of Tinidazole in both bulk drug and pharmaceutical formulations due to its simplicity, sensitivity, and cost-effectiveness.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-07-23
DOI
https://doi.org/10.5281/zenodo.16359466
Primary Topic
Transport and Economic Policies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

To Development and Validation RP-HPLC Method for Tinidazole in Bulk and Pharmaceutical Formulation.

Zenodo (CERN European Organization for Nuclear Research)
Transport and Economic Policies
article

To Development and Validation RP-HPLC Method for Tinidazole in Bulk and Pharmaceutical Formulation.

article en

Abstract

A simple, precise, accurate, and robust Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) method was developed and validated for the quantitative estimation of Tinidazole in bulk and pharmaceutical dosage forms. Chromatographic separation was achieved using a mobile phase of Acetonitrile and Water (90:10 v/v), with the detection wavelength set at 270 nm. The method demonstrated excellent linearity in the concentration range of 5–30 µg/ml, with a correlation coefficient (r²) of 0.9996. The Limit of Detection (LOD) and Limit of Quantitation (LOQ) were found to be 2.5070 µg/ml and 7.5912 µg/ml respectively. Validation parameters such as system suitability, specificity, accuracy, precision (intra-day and inter-day), robustness, and sensitivity were conducted in accordance with ICH guidelines, confirming the reliability and reproducibility of the method. Recovery studies showed results within the acceptable range, indicating no interference from excipients. The proposed method is suitable for routine analysis of Tinidazole in both bulk drug and pharmaceutical formulations due to its simplicity, sensitivity, and cost-effectiveness.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 38%
Transport and Economic Policies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

To Development and Validation RP-HPLC Method for Tinidazole in Bulk and Pharmaceutical Formulation. · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS