DESIGN A NON-INVASIVE BLOOD GLUCOSE MONITOR USING INFRARED SPECTRUM

The incidence of Type 2 Diabetes mellitus (T2DM) is progressively escalating, and the increasing susceptibility to this ailment in India underscores the considerable health obstacle it presents to individuals and families in the country. According to International Diabetic Federation, 537 million adults are currently living with diabetes, and this will further increase to more than 700 million by 2045. T2DM is not cured, it can only be controlled with medication and/or insulin therapy. T2DM patients regularly monitor their blood glucose by glucometer, which is invasive and painful method, required blood sample and also it is cost effective for low-income group of family. In this context, our study was aimed to design a non-invasive blood glucose measuring instrument. Blood glucose monitoring was divided into invasive and non-invasive method of 10 nondiabetic persons and 10 diabetic persons. In invasive blood glucose measurement was done by glucometer and also HbA1c measured by semi-auto analyzer. Non-invasive blood glucose monitoring was performed using our own designed non-invasive glucometer using infrared (IR) of 960 nm wave length, photo diode, operational amplifier (OPAMP), and light-emitting diode (LED). From the invasive method mean blood glucose and HbA1c for nondiabetic persons are 96.20±1.24, 4.86±0.12 and for diabetic persons are 225.20±2.75, 9.41±0.38 respectively. Our own designed non-invasive glucose sensor identified only hypo and hyperglycemia when IR passed through fingertip. It has been concluded that non-invasive blood glucose sensor sensed here only qualitative manner but required more specified for quantitative measurement.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-09-01
DOI
https://doi.org/10.5281/zenodo.15629380
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DESIGN A NON-INVASIVE BLOOD GLUCOSE MONITOR USING INFRARED SPECTRUM

Zenodo (CERN European Organization for Nuclear Research)
Spectroscopy Techniques in Biomedical and Chemical Research
article

DESIGN A NON-INVASIVE BLOOD GLUCOSE MONITOR USING INFRARED SPECTRUM

article en

Abstract

The incidence of Type 2 Diabetes mellitus (T2DM) is progressively escalating, and the increasing susceptibility to this ailment in India underscores the considerable health obstacle it presents to individuals and families in the country. According to International Diabetic Federation, 537 million adults are currently living with diabetes, and this will further increase to more than 700 million by 2045. T2DM is not cured, it can only be controlled with medication and/or insulin therapy. T2DM patients regularly monitor their blood glucose by glucometer, which is invasive and painful method, required blood sample and also it is cost effective for low-income group of family. In this context, our study was aimed to design a non-invasive blood glucose measuring instrument. Blood glucose monitoring was divided into invasive and non-invasive method of 10 nondiabetic persons and 10 diabetic persons. In invasive blood glucose measurement was done by glucometer and also HbA1c measured by semi-auto analyzer. Non-invasive blood glucose monitoring was performed using our own designed non-invasive glucometer using infrared (IR) of 960 nm wave length, photo diode, operational amplifier (OPAMP), and light-emitting diode (LED). From the invasive method mean blood glucose and HbA1c for nondiabetic persons are 96.20±1.24, 4.86±0.12 and for diabetic persons are 225.20±2.75, 9.41±0.38 respectively. Our own designed non-invasive glucose sensor identified only hypo and hyperglycemia when IR passed through fingertip. It has been concluded that non-invasive blood glucose sensor sensed here only qualitative manner but required more specified for quantitative measurement.

Zenodo (CERN European Organization for Nuclear Research)
Rajendra Hospital (IN), Seva Mandir (IN), CDA College (CY)
No poverty
Openalex Percentile: Top 47%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.