REMOVAL OF SOME CONTAMINANTS FROM PRE COAGULATED SEMI-AEROBIC LEACHATE USING MEMBRANE FILTER

Membrane filtration process for water treatment has been well established. However, its application on leachate effluent treatment after coagulation process is quite limited. The present paper investigated the suitability of the coagulation process on leachate effluent treatment generated from the Pulau Burung sanitary landfill site. Three types of membrane were used in this study, namely, nylon, resin and poly-propylene (PP). The pore sizes of membranes were 1µm and 5 µm. The effects of different filtration rates on leachate treatment were studied. The parameters studied were chemical oxygen demand (COD), colour, suspended solids (SS), and ammoniacal nitrogen (NH4N). Poly-aluminium chloride was used as a coagulant in the coagulation and flocculation processes. Results indicate that PP membrane with pore size 1µm gave the best performance in reducing all the parameters, whereas the nylon membrane gave the poorest results. The filtration rate of 100mL/min exhibited the highest removal efficiency. PP membrane with pore size of 1µm at a filtration rate of 100mL/min is the most effective membrane to remove COD, colour, SS and NH4N.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-06-23
DOI
https://doi.org/10.5281/zenodo.15724077
Primary Topic
Membrane Separation Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

REMOVAL OF SOME CONTAMINANTS FROM PRE COAGULATED SEMI-AEROBIC LEACHATE USING MEMBRANE FILTER

Zenodo (CERN European Organization for Nuclear Research)
Membrane Separation Technologies
article

REMOVAL OF SOME CONTAMINANTS FROM PRE COAGULATED SEMI-AEROBIC LEACHATE USING MEMBRANE FILTER

article en

Abstract

Membrane filtration process for water treatment has been well established. However, its application on leachate effluent treatment after coagulation process is quite limited. The present paper investigated the suitability of the coagulation process on leachate effluent treatment generated from the Pulau Burung sanitary landfill site. Three types of membrane were used in this study, namely, nylon, resin and poly-propylene (PP). The pore sizes of membranes were 1µm and 5 µm. The effects of different filtration rates on leachate treatment were studied. The parameters studied were chemical oxygen demand (COD), colour, suspended solids (SS), and ammoniacal nitrogen (NH4N). Poly-aluminium chloride was used as a coagulant in the coagulation and flocculation processes. Results indicate that PP membrane with pore size 1µm gave the best performance in reducing all the parameters, whereas the nylon membrane gave the poorest results. The filtration rate of 100mL/min exhibited the highest removal efficiency. PP membrane with pore size of 1µm at a filtration rate of 100mL/min is the most effective membrane to remove COD, colour, SS and NH4N.

Zenodo (CERN European Organization for Nuclear Research)
Clean water and sanitation
Openalex Percentile: Top 57%
Membrane Separation Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

REMOVAL OF SOME CONTAMINANTS FROM PRE COAGULATED SEMI-AEROBIC LEACHATE USING MEMBRANE FILTER · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS