ThrombUS+ D4.5: Testing, signal quality and performance enhancement of the wearable sensor network

The aim of this document is to define testing protocols and procedures, as well as to describe the test resultsfor individual modules of the wearable sensor network (WSN), in order to ensure compliance with systemand user requirements. The document focuses on testing four components of the wearable sensors network(WSN): the Electrical Impedance Module (EIM), the Light Rheography Module (LRM), the Limb ActivityModule (LAM), and the textile wearable used for mounting all sensors.The hardware testing of electrical impedance module (EIM), light rheography mpodule (LRM) and limbactivity module (LAM), covering both the measurement performance and device’s general functionality,showed that all devices are sufficiently accurate, perform as expected and cover all user and systemrequirements defined in D2.3All test results are presented in protocol tables, which indicate which requirements are validated by specifictests. Where certain tests require more detailed explanation, this is provided below the corresponding tables.Additionally, the document includes demonstration sections for each module, aimed at showcasing thesystems and their user interfaces in operation.The functional testing of the textile wearable of the ThrombUS+ wearable sensor network showed that thedesign is suitable for integrating all systems developed in WP3 and WP4 effectively and ergonomically. Thecleaning procedure tests of wearable showed that the prototype sustained its mechanical and electricalproperties after the cleaning procedures.This document will be updated as necessary throughout the duration of the project, incorporating relevantinformation, issues, and procedural changes. Each time the document is revised, all partners will be dulyinformed of the updates and the changes made compared to the previous version.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-08-02
DOI
https://doi.org/10.5281/zenodo.16656680
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ThrombUS+ D4.5: Testing, signal quality and performance enhancement of the wearable sensor network

Zenodo (CERN European Organization for Nuclear Research)
Advanced Sensor and Energy Harvesting Materials
article

ThrombUS+ D4.5: Testing, signal quality and performance enhancement of the wearable sensor network

article en

Abstract

The aim of this document is to define testing protocols and procedures, as well as to describe the test resultsfor individual modules of the wearable sensor network (WSN), in order to ensure compliance with systemand user requirements. The document focuses on testing four components of the wearable sensors network(WSN): the Electrical Impedance Module (EIM), the Light Rheography Module (LRM), the Limb ActivityModule (LAM), and the textile wearable used for mounting all sensors.The hardware testing of electrical impedance module (EIM), light rheography mpodule (LRM) and limbactivity module (LAM), covering both the measurement performance and device’s general functionality,showed that all devices are sufficiently accurate, perform as expected and cover all user and systemrequirements defined in D2.3All test results are presented in protocol tables, which indicate which requirements are validated by specifictests. Where certain tests require more detailed explanation, this is provided below the corresponding tables.Additionally, the document includes demonstration sections for each module, aimed at showcasing thesystems and their user interfaces in operation.The functional testing of the textile wearable of the ThrombUS+ wearable sensor network showed that thedesign is suitable for integrating all systems developed in WP3 and WP4 effectively and ergonomically. Thecleaning procedure tests of wearable showed that the prototype sustained its mechanical and electricalproperties after the cleaning procedures.This document will be updated as necessary throughout the duration of the project, incorporating relevantinformation, issues, and procedural changes. Each time the document is revised, all partners will be dulyinformed of the updates and the changes made compared to the previous version.

Zenodo (CERN European Organization for Nuclear Research)
Optech (Canada) (CA), Democritus University of Thrace (GR), Tampere University (FI), Kaunas University of Technology (LT), Diamed Medizintechnik (Germany) (DE), Athena Research and Innovation Center In Information Communication & Knowledge Technologies (GR)
Industry, innovation and infrastructure
Openalex Percentile: Top 54%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.