Compton profile of Ta for 59.54 keV gamma radiation source for industrial applications

Abstract- The Compton profile of Tantalum has been determined from the measured differential cross sections at 165°using a high resolution hyper pure germanium detector for 59.54 keV gamma rays from 241Am source. A 99.9% purethin Ta foil was used in measuring the scattering cross sections. A personal computer based 8K-multi-channel analyzerwas used to record the data. The Compton profiles were calculated using these experimental data by employing thetechniques of Eisenberger and Reed as well as Ribberfors. The results were found to agree with the theoretical values ofBiggs et al and Fernandez within the range of experimental errors. Understanding the Compton profile throughCompton scattering can be used in industry to optimize the performance of tantalum-based capacitors and otherelectronic components. The knowledge gained from Compton profile studies can also be applied to optimize industrialprocesses involving tantalum, such as metal fabrication, coating, and processing.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-08-02
DOI
https://doi.org/10.5281/zenodo.16728331
Primary Topic
X-ray Spectroscopy and Fluorescence Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Compton profile of Ta for 59.54 keV gamma radiation source for industrial applications

Zenodo (CERN European Organization for Nuclear Research)
X-ray Spectroscopy and Fluorescence Analysis
article

Compton profile of Ta for 59.54 keV gamma radiation source for industrial applications

article en

Abstract

Abstract- The Compton profile of Tantalum has been determined from the measured differential cross sections at 165°using a high resolution hyper pure germanium detector for 59.54 keV gamma rays from 241Am source. A 99.9% purethin Ta foil was used in measuring the scattering cross sections. A personal computer based 8K-multi-channel analyzerwas used to record the data. The Compton profiles were calculated using these experimental data by employing thetechniques of Eisenberger and Reed as well as Ribberfors. The results were found to agree with the theoretical values ofBiggs et al and Fernandez within the range of experimental errors. Understanding the Compton profile throughCompton scattering can be used in industry to optimize the performance of tantalum-based capacitors and otherelectronic components. The knowledge gained from Compton profile studies can also be applied to optimize industrialprocesses involving tantalum, such as metal fabrication, coating, and processing.

Zenodo (CERN European Organization for Nuclear Research)
Visvesvaraya Technological University (IN)
Industry, innovation and infrastructure
Openalex Percentile: Top 39%
X-ray Spectroscopy and Fluorescence Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.