RELIABILITY ASSESSMENT AND IMPROVEMENT OF 11KV DISTRIBUTION SYSTEM WITH DISTRIBUTED GENERATION DEPLOYMENT

Interruptions which are largely unavoidable contribute to the unavailability of power and the inability of the power system meeting the electricity demands of the consumers. The incessant interruptions and unstable power supply from the grid could be as a result of unreliable nature of the distribution system, which is unhealthy to the consumers, power system equipment and the utility company. Therefore, to minimize this unreliability issues, the power system planners need comes up with an upgrading approach with a view of improving the reliability of the distribution system. In this paper, reliability assessment of Okwuzi, Omoku 11kV distribution system was carried out using one year (January to December,2023) outage frequency and duration data gotten from the utility, in order to ascertain the reliability performance of the system by determining key reliability indices, and proposes penetration of distributed generation if the indices fail the set standard. Electrical Transient Analyzer Program (ETAP) software was used for the simulation. This was done by carrying out reliability study of the existing 11kV distribution network using embedded analytical equations in ETAP; reliability indices were determined, and improved upon by the penetration of PSO optimized distributed generation (1.63MVA) in bus 9 and reliability study was performed with DG. The results obtained indicate that when DG was injected into the system, average failure rate and average outage duration at load point 6, reduces by 34.2% and 23.8% respectively, then, so on up to load point 14. Similarly, at the penetration of DG, there were significant improvement in the customer’s-oriented reliability indices; SAIFI, 0.4747 to 0.2535f/yr, SAIDI, 13.56 to 8.2585hr/yr, CAIDI, 32.577 to 28. 581hr.intr and EENS, 56.216 to 43.376MWhr/yr. The availability index ASAI improved from 86.8 % to 99.85% which is close to the 99.9989% IEEE benchmark

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-11-12
DOI
https://doi.org/10.5281/zenodo.14101741
Primary Topic
Power System Reliability and Maintenance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RELIABILITY ASSESSMENT AND IMPROVEMENT OF 11KV DISTRIBUTION SYSTEM WITH DISTRIBUTED GENERATION DEPLOYMENT

Zenodo (CERN European Organization for Nuclear Research)
Power System Reliability and Maintenance
article

RELIABILITY ASSESSMENT AND IMPROVEMENT OF 11KV DISTRIBUTION SYSTEM WITH DISTRIBUTED GENERATION DEPLOYMENT

article en

Abstract

Interruptions which are largely unavoidable contribute to the unavailability of power and the inability of the power system meeting the electricity demands of the consumers. The incessant interruptions and unstable power supply from the grid could be as a result of unreliable nature of the distribution system, which is unhealthy to the consumers, power system equipment and the utility company. Therefore, to minimize this unreliability issues, the power system planners need comes up with an upgrading approach with a view of improving the reliability of the distribution system. In this paper, reliability assessment of Okwuzi, Omoku 11kV distribution system was carried out using one year (January to December,2023) outage frequency and duration data gotten from the utility, in order to ascertain the reliability performance of the system by determining key reliability indices, and proposes penetration of distributed generation if the indices fail the set standard. Electrical Transient Analyzer Program (ETAP) software was used for the simulation. This was done by carrying out reliability study of the existing 11kV distribution network using embedded analytical equations in ETAP; reliability indices were determined, and improved upon by the penetration of PSO optimized distributed generation (1.63MVA) in bus 9 and reliability study was performed with DG. The results obtained indicate that when DG was injected into the system, average failure rate and average outage duration at load point 6, reduces by 34.2% and 23.8% respectively, then, so on up to load point 14. Similarly, at the penetration of DG, there were significant improvement in the customer’s-oriented reliability indices; SAIFI, 0.4747 to 0.2535f/yr, SAIDI, 13.56 to 8.2585hr/yr, CAIDI, 32.577 to 28. 581hr.intr and EENS, 56.216 to 43.376MWhr/yr. The availability index ASAI improved from 86.8 % to 99.85% which is close to the 99.9989% IEEE benchmark

Zenodo (CERN European Organization for Nuclear Research)
University of Port Harcourt (NG)
Affordable and clean energy
Openalex Percentile: Top 53%
Power System Reliability and Maintenance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.