RP-HPLC method for the estimation of Lobeglitazone sulphate in pharmaceutical dosage form

A simple, rapid, accurate and precise RP-HPLC method was developed and validated for the determination of Lobeglitazone sulfate in table dosage form. Chromatographic analysis of the drug was achieved on Shimadzu HPLC comprising of LC- 20 AD binary gradient pump, a variable wavelength programmable SPD-20A detector and SCL system controller. Kromasil column (250 mm x 4.6 mm, 5 μ) as stationary phase with mobile phase consisting of 1% glacial acetic acid and acetonitrile in the ratio of 30 : 70 v/v. The method showed a good linear response in the concentration range of 10-60 μg/ml with correlation coefficient of 0.9990. The flow rate was maintained at 1.0 ml/min and detection was carried out at 254 nm. The retention time was 4.211 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, solution stability, selectivity and sensitivity. The results obtained in the study were within the limits of ICH guidelines and hence this method can be used for the determination of lobeglitazone sulfate in tablet formulation.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-11-30
DOI
https://doi.org/10.5281/zenodo.14760489
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RP-HPLC method for the estimation of Lobeglitazone sulphate in pharmaceutical dosage form

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

RP-HPLC method for the estimation of Lobeglitazone sulphate in pharmaceutical dosage form

article en

Abstract

A simple, rapid, accurate and precise RP-HPLC method was developed and validated for the determination of Lobeglitazone sulfate in table dosage form. Chromatographic analysis of the drug was achieved on Shimadzu HPLC comprising of LC- 20 AD binary gradient pump, a variable wavelength programmable SPD-20A detector and SCL system controller. Kromasil column (250 mm x 4.6 mm, 5 μ) as stationary phase with mobile phase consisting of 1% glacial acetic acid and acetonitrile in the ratio of 30 : 70 v/v. The method showed a good linear response in the concentration range of 10-60 μg/ml with correlation coefficient of 0.9990. The flow rate was maintained at 1.0 ml/min and detection was carried out at 254 nm. The retention time was 4.211 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, solution stability, selectivity and sensitivity. The results obtained in the study were within the limits of ICH guidelines and hence this method can be used for the determination of lobeglitazone sulfate in tablet formulation.

Zenodo (CERN European Organization for Nuclear Research)
National Institute of Pharmaceutical Education and Research - Ahmedabad (IN)
Clean water and sanitation
Openalex Percentile: Top 62%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.