Reverse Phase Liquid Chromatography Method Development and Validation for Impurity Profiling of Donepezil Drug

Reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for concurrent detection of five impurities in donepezil hydrochloride. Using the method employed an Hypersil ODS, 25 cm x 4.6 mm, 5.0µm), chosen for its superior retention, resolution, and reproducibility. The mobile phase was optimized to a gradient program consisting of solution A as 10 mM diammonium hydrogen orthophosphate in water (pH 6.0) and Solution B as acetonitrile and methanol (85:15v/v). This method demonstrated excellent peak symmetry, resolution, and reproducibility at wavelength of 230 nm and a column temperature at 35°C. Despite initial difficulties with peak shape, the final conditions produced reliable and high-quality chromatograms for impurity profiling. The RP-HPLC method effectively quantifies five impurities (Imp-A to Imp-E) and satisfies key validation criteria like accuracy, precision, linearity, specificity, and system suitability. It shows robust performance, though some impurities are challenging to detect at lower concentrations. System suitability tests confirm consistency in peak areas and retention times, validating the method as both reliable and cost-effective for impurity analysis in donepezil hydrochloride, ensuring the drug’s quality and safety.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-02-14
DOI
https://doi.org/10.5281/zenodo.14871560
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reverse Phase Liquid Chromatography Method Development and Validation for Impurity Profiling of Donepezil Drug

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

Reverse Phase Liquid Chromatography Method Development and Validation for Impurity Profiling of Donepezil Drug

article en

Abstract

Reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for concurrent detection of five impurities in donepezil hydrochloride. Using the method employed an Hypersil ODS, 25 cm x 4.6 mm, 5.0µm), chosen for its superior retention, resolution, and reproducibility. The mobile phase was optimized to a gradient program consisting of solution A as 10 mM diammonium hydrogen orthophosphate in water (pH 6.0) and Solution B as acetonitrile and methanol (85:15v/v). This method demonstrated excellent peak symmetry, resolution, and reproducibility at wavelength of 230 nm and a column temperature at 35°C. Despite initial difficulties with peak shape, the final conditions produced reliable and high-quality chromatograms for impurity profiling. The RP-HPLC method effectively quantifies five impurities (Imp-A to Imp-E) and satisfies key validation criteria like accuracy, precision, linearity, specificity, and system suitability. It shows robust performance, though some impurities are challenging to detect at lower concentrations. System suitability tests confirm consistency in peak areas and retention times, validating the method as both reliable and cost-effective for impurity analysis in donepezil hydrochloride, ensuring the drug’s quality and safety.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 52%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.