EVALUATING OPERATIONAL CONDITION RELIABILITY THROUGH LOAD CONDITION FORECASTING

This research investigates the operational reliability of transformers in the Qibray 35/6 substation by forecasting load conditions using Feed Forward Neural Networks (FNN). The study focuses on analyzing transformer load behavior over time and predicts when the load will exceed critical thresholds. Using primary data from 2021 to 2023, the study develops a forecasting algorithm based on FNN, which is used to predict when transformer loads exceed 85% of their nominal capacity. Results indicate that in the near future, the transformer load will enter a hazardous zone, reaching over 0.8 after 8 years and fully entering the critical range after 12 years. The study emphasizes the importance of load redistribution and the installation of new equipment to ensure the continuous and reliable operation of the electrical grid

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-11-22
DOI
https://doi.org/10.5281/zenodo.14202056
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EVALUATING OPERATIONAL CONDITION RELIABILITY THROUGH LOAD CONDITION FORECASTING

Zenodo (CERN European Organization for Nuclear Research)
Power Transformer Diagnostics and Insulation
article

EVALUATING OPERATIONAL CONDITION RELIABILITY THROUGH LOAD CONDITION FORECASTING

article en

Abstract

This research investigates the operational reliability of transformers in the Qibray 35/6 substation by forecasting load conditions using Feed Forward Neural Networks (FNN). The study focuses on analyzing transformer load behavior over time and predicts when the load will exceed critical thresholds. Using primary data from 2021 to 2023, the study develops a forecasting algorithm based on FNN, which is used to predict when transformer loads exceed 85% of their nominal capacity. Results indicate that in the near future, the transformer load will enter a hazardous zone, reaching over 0.8 after 8 years and fully entering the critical range after 12 years. The study emphasizes the importance of load redistribution and the installation of new equipment to ensure the continuous and reliable operation of the electrical grid

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Openalex Percentile: Top 65%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.