Characterization and Clinical Outcomes of High-Risk Device-Related Thrombus in the Amulet IDE Trial.

Background Characteristics of device-related thrombus (DRT) may differ between types of left atrial appendage occlusion devices, and the association of different DRT characteristics to clinical outcomes is largely unknown.Objectives The incidence, characteristics, and clinical outcomes through 5 years of high- and low-risk DRTs were assessed in the Amulet IDE trial (AMPLATZER Amulet Left Atrial Appendage Occluder [LAAO] Investigational Device Exemption [IDE] Trial).Methods An independent core laboratory analyzed all available images at the required 45-day and 12-month visits, and clinical events were reported through 5 years' post-left atrial appendage occlusion.Results Of the 1,788 patients with a successful device implant, DRT was observed in 3.3% (30 of 903) and 4.5% (40 of 885) of Amulet and Watchman 2.5 device patients throughout 12 months, respectively (P = 0.192). DRTs were successfully classified as high risk if pedunculated, mobile, >3 mm in thickness, or without continuation onto the left atrial wall. A significantly higher incidence of high-risk DRTs was observed on the Watchman 2.5 device (4.0% [35 of 885]) compared with the Amulet occluder (2.2% [20 of 903]) (P = 0.030). Most low-risk DRTs resolved (12 of 15), whereas high-risk DRTs remained mostly unresolved (34 of 55). Through 5 years, all clinical outcome rates were numerically higher in the high-risk DRT group compared with the low-risk DRT or no-DRT group; significance was observed in the composite of stroke, systemic embolism, or cardiovascular death (30.4% vs 19.9%; HR: 1.74; 95% CI: 1.03-2.92; P = 0.037) and cardiovascular death (26.4% vs 14.5%, HR: 2.09; 95% CI: 1.20-3.66; P = 0.009).Conclusions High-risk DRTs were observed in a higher number of Watchman 2.5 device patients compared with Amulet occluder patients. The composite of stroke, systemic embolism, or cardiovascular death occurred more often in patients with high-risk DRTs compared with those with low-risk DRTs or no DRTs. (AMPLATZER Amulet Left Atrial Appendage Occluder [LAAO] Investigational Device Exemption [Amulet IDE Trial]; NCT02879448).

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-04-23
DOI
https://doi.org/10.48620/87487
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization and Clinical Outcomes of High-Risk Device-Related Thrombus in the Amulet IDE Trial.

Open Access CRIS of the University of Bern
Atrial Fibrillation Management and Outcomes
article

Characterization and Clinical Outcomes of High-Risk Device-Related Thrombus in the Amulet IDE Trial.

article en

Abstract

Background Characteristics of device-related thrombus (DRT) may differ between types of left atrial appendage occlusion devices, and the association of different DRT characteristics to clinical outcomes is largely unknown.Objectives The incidence, characteristics, and clinical outcomes through 5 years of high- and low-risk DRTs were assessed in the Amulet IDE trial (AMPLATZER Amulet Left Atrial Appendage Occluder [LAAO] Investigational Device Exemption [IDE] Trial).Methods An independent core laboratory analyzed all available images at the required 45-day and 12-month visits, and clinical events were reported through 5 years' post-left atrial appendage occlusion.Results Of the 1,788 patients with a successful device implant, DRT was observed in 3.3% (30 of 903) and 4.5% (40 of 885) of Amulet and Watchman 2.5 device patients throughout 12 months, respectively (P = 0.192). DRTs were successfully classified as high risk if pedunculated, mobile, >3 mm in thickness, or without continuation onto the left atrial wall. A significantly higher incidence of high-risk DRTs was observed on the Watchman 2.5 device (4.0% [35 of 885]) compared with the Amulet occluder (2.2% [20 of 903]) (P = 0.030). Most low-risk DRTs resolved (12 of 15), whereas high-risk DRTs remained mostly unresolved (34 of 55). Through 5 years, all clinical outcome rates were numerically higher in the high-risk DRT group compared with the low-risk DRT or no-DRT group; significance was observed in the composite of stroke, systemic embolism, or cardiovascular death (30.4% vs 19.9%; HR: 1.74; 95% CI: 1.03-2.92; P = 0.037) and cardiovascular death (26.4% vs 14.5%, HR: 2.09; 95% CI: 1.20-3.66; P = 0.009).Conclusions High-risk DRTs were observed in a higher number of Watchman 2.5 device patients compared with Amulet occluder patients. The composite of stroke, systemic embolism, or cardiovascular death occurred more often in patients with high-risk DRTs compared with those with low-risk DRTs or no DRTs. (AMPLATZER Amulet Left Atrial Appendage Occluder [LAAO] Investigational Device Exemption [Amulet IDE Trial]; NCT02879448).

Open Access CRIS of the University of Bern
Good health and well-being
Openalex Percentile: Top 38%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.