Influence of dental implant clinical experience on the accuracy of robot-assisted immediate implant placement: an in vitro study.

Objectives To assess the accuracy and effectiveness among operators with different levels of experience in a robot-assisted immediate implant surgery.Materials And Methods The study included four participants who had received dental training at the same institution but have varying levels of clinical experience in implant dentistry, denoted as undergraduate student (UG), dental resident (DR), specialist with no robot experience (IS) and specialist with robot experience (RS). Following comprehensive theoretical training in robot-assisted implant operation, each operator participated in five robotic-assisted implant procedures at 21 sites, resulting in the implant surgery of a total of 20 implants. Subsequently, the accuracy of the implants was assessed by analyzing the preoperative planning and the postoperative CBCT scans, and the time required for each procedure was also recorded.Results Angular deviation in UG, DR, IS and RS group was 0.82 ± 0.27°, 0.55 ± 0.27°, 0.83 ± 0.27°, and 0.56 ± 0.36°, respectively. The total deviation of the implant platform point was 0.28 ± 0.10 mm, 0.26 ± 0.16 mm, 0.34 ± 0.08 mm and 0.31 ± 0.06 mm, respectively. The total deviation of the apical point was 0.30 ± 0.08 mm, 0.25 ± 0.18 mm, 0.31 ± 0.09 mm, and 0.31 ± 0.05 mm, respectively. The time spent was 10.37 ± 0.57 min, 10.56 ± 1.77 min, 9.93 ± 0.78 min, and 11.76 ± 0.78 min for each operator. As the number of operations increased, the operation time decreased, but there was no significant difference in implant accuracy between the different groups.Conclusions Within the scope of this study, robot-assisted implant surgery demonstrated high accuracy, with no significant differences in performance between operators with varying levels of clinical experience or implant robot-user experience. Furthermore, the learning curve for robotic implant surgery is steep and consistent.Clinical Relevance Robot-assisted implant surgery demonstrates consistent high accuracy across operators of varying clinical and robotic experience levels, highlighting its potential to standardize procedures and enhance predictability in clinical outcomes.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-09-05
DOI
https://doi.org/10.48620/43093
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of dental implant clinical experience on the accuracy of robot-assisted immediate implant placement: an in vitro study.

Open Access CRIS of the University of Bern
Dental Implant Techniques and Outcomes
article

Influence of dental implant clinical experience on the accuracy of robot-assisted immediate implant placement: an in vitro study.

article en

Abstract

Objectives To assess the accuracy and effectiveness among operators with different levels of experience in a robot-assisted immediate implant surgery.Materials And Methods The study included four participants who had received dental training at the same institution but have varying levels of clinical experience in implant dentistry, denoted as undergraduate student (UG), dental resident (DR), specialist with no robot experience (IS) and specialist with robot experience (RS). Following comprehensive theoretical training in robot-assisted implant operation, each operator participated in five robotic-assisted implant procedures at 21 sites, resulting in the implant surgery of a total of 20 implants. Subsequently, the accuracy of the implants was assessed by analyzing the preoperative planning and the postoperative CBCT scans, and the time required for each procedure was also recorded.Results Angular deviation in UG, DR, IS and RS group was 0.82 ± 0.27°, 0.55 ± 0.27°, 0.83 ± 0.27°, and 0.56 ± 0.36°, respectively. The total deviation of the implant platform point was 0.28 ± 0.10 mm, 0.26 ± 0.16 mm, 0.34 ± 0.08 mm and 0.31 ± 0.06 mm, respectively. The total deviation of the apical point was 0.30 ± 0.08 mm, 0.25 ± 0.18 mm, 0.31 ± 0.09 mm, and 0.31 ± 0.05 mm, respectively. The time spent was 10.37 ± 0.57 min, 10.56 ± 1.77 min, 9.93 ± 0.78 min, and 11.76 ± 0.78 min for each operator. As the number of operations increased, the operation time decreased, but there was no significant difference in implant accuracy between the different groups.Conclusions Within the scope of this study, robot-assisted implant surgery demonstrated high accuracy, with no significant differences in performance between operators with varying levels of clinical experience or implant robot-user experience. Furthermore, the learning curve for robotic implant surgery is steep and consistent.Clinical Relevance Robot-assisted implant surgery demonstrates consistent high accuracy across operators of varying clinical and robotic experience levels, highlighting its potential to standardize procedures and enhance predictability in clinical outcomes.

Open Access CRIS of the University of Bern
University of Dental Medicine (MM)
Openalex Percentile: Top 49%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.