Physiological team dynamics explored: physiological synchrony in medical simulation training.

Introduction For researchers and medical simulation trainers, measuring team dynamics is vital for providing targeted feedback that can lead to improved patient outcomes. It is also valuable for research, such as investigating which dynamics benefit team performance. Traditional assessment methods, such as questionnaires and observations, are often subjective and static, lacking the ability to capture team dynamics. To address these shortcomings, this study explores the use of physiological synchrony (PS) measured through electrocardiogram (ECG) data to evaluate team dynamics automated and in high-resolution.Methods A multicentre observational field study was conducted involving 214 medical first responders during mixed reality (MR) mass casualty training sessions. Participants were equipped with electrocardiogram (ECG) sensors and MR gear. The study measured dyadic PS using heart rate (HR), root mean square of successive differences (RMSSD), and standard deviation of NN intervals (SDNN). Data were collected at high frequency and analysed using dynamic time warping (dtw) to assess fluctuations in PS.Results Findings indicate that PS varies significantly by task nature, with higher synchrony during cooperative tasks compared to baseline. Different ECG metrics offered unique insights into team dynamics. Proximity and scenario conditions influenced PS, with closer teamwork leading to higher PS. Smaller sampling intervals (e.g. 5 s) provided a detailed view of PS fluctuations over time.Discussion The results demonstrate the potential of PS as an indicator of team performance and cohesion. High-resolution monitoring provides detailed insights into team dynamics, offering high-resolution feedback that traditional methods cannot provide. The integration of physiological measures into training programmes can enhance team performance by providing objective, high-resolution data.Conclusion This study shows that PS, measured by ECG data, is sensitive to medical team activities, offering insights into team dynamics. Different ECG metrics highlight various aspects of team performance, and high-resolution monitoring captures detailed dynamics. Further research is needed to validate these findings across diverse scenarios. This approach could improve training methodologies, resulting in better-prepared medical teams and improved patient care outcomes.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-03-01
DOI
https://doi.org/10.48620/86827
Primary Topic
Simulation-Based Education in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physiological team dynamics explored: physiological synchrony in medical simulation training.

Open Access CRIS of the University of Bern
Simulation-Based Education in Healthcare
article

Physiological team dynamics explored: physiological synchrony in medical simulation training.

article en

Abstract

Introduction For researchers and medical simulation trainers, measuring team dynamics is vital for providing targeted feedback that can lead to improved patient outcomes. It is also valuable for research, such as investigating which dynamics benefit team performance. Traditional assessment methods, such as questionnaires and observations, are often subjective and static, lacking the ability to capture team dynamics. To address these shortcomings, this study explores the use of physiological synchrony (PS) measured through electrocardiogram (ECG) data to evaluate team dynamics automated and in high-resolution.Methods A multicentre observational field study was conducted involving 214 medical first responders during mixed reality (MR) mass casualty training sessions. Participants were equipped with electrocardiogram (ECG) sensors and MR gear. The study measured dyadic PS using heart rate (HR), root mean square of successive differences (RMSSD), and standard deviation of NN intervals (SDNN). Data were collected at high frequency and analysed using dynamic time warping (dtw) to assess fluctuations in PS.Results Findings indicate that PS varies significantly by task nature, with higher synchrony during cooperative tasks compared to baseline. Different ECG metrics offered unique insights into team dynamics. Proximity and scenario conditions influenced PS, with closer teamwork leading to higher PS. Smaller sampling intervals (e.g. 5 s) provided a detailed view of PS fluctuations over time.Discussion The results demonstrate the potential of PS as an indicator of team performance and cohesion. High-resolution monitoring provides detailed insights into team dynamics, offering high-resolution feedback that traditional methods cannot provide. The integration of physiological measures into training programmes can enhance team performance by providing objective, high-resolution data.Conclusion This study shows that PS, measured by ECG data, is sensitive to medical team activities, offering insights into team dynamics. Different ECG metrics highlight various aspects of team performance, and high-resolution monitoring captures detailed dynamics. Further research is needed to validate these findings across diverse scenarios. This approach could improve training methodologies, resulting in better-prepared medical teams and improved patient care outcomes.

Open Access CRIS of the University of Bern
Global Health Strategies (United States) (US)
Openalex Percentile: Top 44%
Simulation-Based Education in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.