Genomic analysis of Legionella pneumophila in the drinking water system of a large building over 25 years

Legionella pneumophila, the causative agent of Legionnaires’ disease, is often found in the plumbing systems of buildings, from where it can be transmitted to humans via inhalation or aspiration of contaminated water drops. Annual routine water sampling from the potable water system of an occupational healthcare building in Basel over 25 years was performed in accordance with national guidelines. Overall, 309 water samples were collected at 38 time points over the period of 25 years. L. pneumophila was recovered from 120 water samples (38.8%) from 26 time points. No clinical infections were recorded during this period. Initial decontamination measures were successful for ~12 years, after which an increase in the total number of Legionella c.f.u. as well as of L. pneumophila-positive sites was noticed in 2007. Whole genome sequencing (WGS) analysis of n=123 isolates from n=113 samples showed all L. pneumophila to be sequence type 45 (sequence-based typing scheme). The isolates are closely related, with only 408 SNPs among all isolates after the bioinformatic removal of recombination events. Over the 25 years, a single lineage deriving from a recent common ancestor colonized the water system of this building. The phylogeny of isolate genomes can be interpreted as inferring good water circulation and possible recolonization from a common source after cleaning, with genome evolution and insertion/loss of large elements evident. Regular monitoring of waterlines in healthcare settings helps to identify concentrations of Legionella spp., and WGS is recommended for detailed investigation.

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2025-05-01
DOI
https://doi.org/10.5167/uzh-278548
Primary Topic
Legionella and Acanthamoeba research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Genomic analysis of Legionella pneumophila in the drinking water system of a large building over 25 years

Zurich Open Repository and Archive (University of Zurich)
Legionella and Acanthamoeba research
article

Genomic analysis of Legionella pneumophila in the drinking water system of a large building over 25 years

article en

Abstract

Legionella pneumophila, the causative agent of Legionnaires’ disease, is often found in the plumbing systems of buildings, from where it can be transmitted to humans via inhalation or aspiration of contaminated water drops. Annual routine water sampling from the potable water system of an occupational healthcare building in Basel over 25 years was performed in accordance with national guidelines. Overall, 309 water samples were collected at 38 time points over the period of 25 years. L. pneumophila was recovered from 120 water samples (38.8%) from 26 time points. No clinical infections were recorded during this period. Initial decontamination measures were successful for ~12 years, after which an increase in the total number of Legionella c.f.u. as well as of L. pneumophila-positive sites was noticed in 2007. Whole genome sequencing (WGS) analysis of n=123 isolates from n=113 samples showed all L. pneumophila to be sequence type 45 (sequence-based typing scheme). The isolates are closely related, with only 408 SNPs among all isolates after the bioinformatic removal of recombination events. Over the 25 years, a single lineage deriving from a recent common ancestor colonized the water system of this building. The phylogeny of isolate genomes can be interpreted as inferring good water circulation and possible recolonization from a common source after cleaning, with genome evolution and insertion/loss of large elements evident. Regular monitoring of waterlines in healthcare settings helps to identify concentrations of Legionella spp., and WGS is recommended for detailed investigation.

Zurich Open Repository and Archive (University of Zurich)
Clean water and sanitation
Openalex Percentile: Top 47%
Legionella and Acanthamoeba research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Genomic analysis of Legionella pneumophila in the drinking water system of a large building over 25 years · Zurich Open Repository and Archive (University of Zurich) (2025) | TGRS Research Map | TGRS