Improving surgical technical skills for emergency fixation of unstable pelvic ring fractures: an experimental study using a pelvic ring fracture simulator

BACKGROUND The management of hemodynamically unstable pelvic ring injuries necessitates surgical intervention, often involving procedures such as external fixation and percutaneous screw placement. Given the infrequent performance of these procedures, regular training is imperative to ensure readiness for emergencies. Our pre- post simulation study aimed to adapt and validate a realistic simulation model for stabilizing unstable pelvic ring injuries, facilitating participants' knowledge retention and procedural confidence enhancement. METHODS A standardized simulator of an unstable pelvic ring utilizing synthetic pelvic bones featuring complete disruption of the symphysis and sacroiliac joint was developed. Trauma surgeons of a level one academic hospital were invited to perform external fixation and emergency sacroiliac screw application under C-arm guidance. Prior to and following the simulation session, participants completed a subjective questionnaire assessing their confidence in emergency interventions on a 10-point Likert scale (10-LS). Objective parameters, such as intraoperative imaging quality, reduction accuracy, and the positioning of screws, wires, and external fixators, were also evaluated as secondary outcome measures. RESULTS Fifteen trauma surgeons (10 residents, 5 consultants) participated in the simulation over the course of one day. The mean total operation time was 20.34 ± 6.06 min, without significant differences between consultants and residents (p = 0.604). The confidence for emergency SI-Screw placement increased significantly after the simulator (10-LS: Before = 3.8 ± 3.08 vs. After = 5.67 ± 2.35; p = 0.002) as well as after external fixation (10-LS: Before = 3.93 ± 2.79 vs. After = 6.07 ± 2.52; p = 0.002). In addition, confidence in (intraoperative) pelvic imaging increased significantly (10-LS: Before = 4.60 ± 3.0 vs. After = 6.53 ± 2.39; p = 0.011). Overall, the model was rated as a realistic simulation of clinical practice (10-LS = 7.87 ± 1.13). CONCLUSIONS Our unstable pelvis fracture model is a tool to practice emergency interventions such as external fixation and percutaneous techniques. Participants benefitted from this in terms of technical instrumentation as well as intraoperative imaging. Further studies are required to validate the objective benefits and improvements that participants undergo through frequent training.

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2024-09-27
DOI
https://doi.org/10.5167/uzh-262768
Primary Topic
Pelvic and Acetabular Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving surgical technical skills for emergency fixation of unstable pelvic ring fractures: an experimental study using a pelvic ring fracture simulator

Zurich Open Repository and Archive (University of Zurich)
Pelvic and Acetabular Injuries
article

Improving surgical technical skills for emergency fixation of unstable pelvic ring fractures: an experimental study using a pelvic ring fracture simulator

article en

Abstract

BACKGROUND The management of hemodynamically unstable pelvic ring injuries necessitates surgical intervention, often involving procedures such as external fixation and percutaneous screw placement. Given the infrequent performance of these procedures, regular training is imperative to ensure readiness for emergencies. Our pre- post simulation study aimed to adapt and validate a realistic simulation model for stabilizing unstable pelvic ring injuries, facilitating participants' knowledge retention and procedural confidence enhancement. METHODS A standardized simulator of an unstable pelvic ring utilizing synthetic pelvic bones featuring complete disruption of the symphysis and sacroiliac joint was developed. Trauma surgeons of a level one academic hospital were invited to perform external fixation and emergency sacroiliac screw application under C-arm guidance. Prior to and following the simulation session, participants completed a subjective questionnaire assessing their confidence in emergency interventions on a 10-point Likert scale (10-LS). Objective parameters, such as intraoperative imaging quality, reduction accuracy, and the positioning of screws, wires, and external fixators, were also evaluated as secondary outcome measures. RESULTS Fifteen trauma surgeons (10 residents, 5 consultants) participated in the simulation over the course of one day. The mean total operation time was 20.34 ± 6.06 min, without significant differences between consultants and residents (p = 0.604). The confidence for emergency SI-Screw placement increased significantly after the simulator (10-LS: Before = 3.8 ± 3.08 vs. After = 5.67 ± 2.35; p = 0.002) as well as after external fixation (10-LS: Before = 3.93 ± 2.79 vs. After = 6.07 ± 2.52; p = 0.002). In addition, confidence in (intraoperative) pelvic imaging increased significantly (10-LS: Before = 4.60 ± 3.0 vs. After = 6.53 ± 2.39; p = 0.011). Overall, the model was rated as a realistic simulation of clinical practice (10-LS = 7.87 ± 1.13). CONCLUSIONS Our unstable pelvis fracture model is a tool to practice emergency interventions such as external fixation and percutaneous techniques. Participants benefitted from this in terms of technical instrumentation as well as intraoperative imaging. Further studies are required to validate the objective benefits and improvements that participants undergo through frequent training.

Zurich Open Repository and Archive (University of Zurich)
Quality Education
Openalex Percentile: Top 43%
Pelvic and Acetabular Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.