Comparison of Thiel-fixed and fresh-frozen temporal bon biomechanics with dynamic synchrotron-based X-ray imaging.
Background The Thiel embalming method offers lifelike tissue preservation, yet its suitability for biomechanical studies remains debated.Methods Here, we investigated two human temporal bones, one Thiel-fixed and one fresh-frozen, using dynamic synchrotron-based X-ray imaging under acoustic stimulation.Findings Both specimens exhibited a linear response at the umbo, but the Thiel-fixed specimen displayed discontinuity after the incudo-malleolar joint, suggesting ossicular chain stiffening. Our findings align well with previous studies indicating potential tissue degradation induced by Thiel-embalming.Interpretation These observations question the use of Thiel-fixed human specimens for biomechanical measurements on the middle ear, especially using dynamic synchrotron-based X-ray imaging. They emphasize the need for further assessment of the impact of Thiel-embalming methods on tissue mechanics.
Institutions
- Carolina Ear, Nose and Throat Clinic (US)
Publication Details
- Journal
- Open Access CRIS of the University of Bern
- Published
- 2025-04-08
- DOI
- https://doi.org/10.48620/87778
- Primary Topic
- Ear Surgery and Otitis Media
- Type
- article
- Field-Weighted Citation Impact
- 0.00