Comparison of Thiel-fixed and fresh-frozen temporal bon biomechanics with dynamic synchrotron-based X-ray imaging.

Background The Thiel embalming method offers lifelike tissue preservation, yet its suitability for biomechanical studies remains debated.Methods Here, we investigated two human temporal bones, one Thiel-fixed and one fresh-frozen, using dynamic synchrotron-based X-ray imaging under acoustic stimulation.Findings Both specimens exhibited a linear response at the umbo, but the Thiel-fixed specimen displayed discontinuity after the incudo-malleolar joint, suggesting ossicular chain stiffening. Our findings align well with previous studies indicating potential tissue degradation induced by Thiel-embalming.Interpretation These observations question the use of Thiel-fixed human specimens for biomechanical measurements on the middle ear, especially using dynamic synchrotron-based X-ray imaging. They emphasize the need for further assessment of the impact of Thiel-embalming methods on tissue mechanics.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-04-08
DOI
https://doi.org/10.48620/87778
Primary Topic
Ear Surgery and Otitis Media
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Thiel-fixed and fresh-frozen temporal bon biomechanics with dynamic synchrotron-based X-ray imaging.

Open Access CRIS of the University of Bern
Ear Surgery and Otitis Media
article

Comparison of Thiel-fixed and fresh-frozen temporal bon biomechanics with dynamic synchrotron-based X-ray imaging.

article en

Abstract

Background The Thiel embalming method offers lifelike tissue preservation, yet its suitability for biomechanical studies remains debated.Methods Here, we investigated two human temporal bones, one Thiel-fixed and one fresh-frozen, using dynamic synchrotron-based X-ray imaging under acoustic stimulation.Findings Both specimens exhibited a linear response at the umbo, but the Thiel-fixed specimen displayed discontinuity after the incudo-malleolar joint, suggesting ossicular chain stiffening. Our findings align well with previous studies indicating potential tissue degradation induced by Thiel-embalming.Interpretation These observations question the use of Thiel-fixed human specimens for biomechanical measurements on the middle ear, especially using dynamic synchrotron-based X-ray imaging. They emphasize the need for further assessment of the impact of Thiel-embalming methods on tissue mechanics.

Open Access CRIS of the University of Bern
Carolina Ear, Nose and Throat Clinic (US)
Openalex Percentile: Top 38%
Ear Surgery and Otitis Media
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of Thiel-fixed and fresh-frozen temporal bon biomechanics with dynamic synchrotron-based X-ray imaging. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS