ICPMS/MS with Benzene Vapor

Benzene vapor was introduced into the reaction cell of an inductively coupled plasma tandem mass spectrometer. By evaporating benzene into the helium supply of the octopole reaction cell, product ion spectra for plasma-based atomic and molecular ions were recorded. Based on these spectra, product ions for the separation of the atomic ions from spectral overlaps from isobaric or molecular ion interferents were selected. Background equivalent concentrations (BECs) or sensitivity ratios for analytes and interferents were compared to on-mass analyses without benzene addition. Depending on the analyte, up to 4 orders of magnitude improvement could be achieved. Specifically, the detection of S and Se could be improved substantially, and their BECs were reduced to the μg/L and ng/L ranges, respectively. The separation of isobaric Rb and Sr isotopes or of CeO+ from Gd+ was less effective with the use of benzene adducts alone. The separation could be substantially improved by using benzene and oxo or water adducts, and analyte/interferent sensitivity ratios greater than 104 were obtained. Finally, the attenuation of 14N2+, interfering with 28Si+, was evaluated under dry plasma conditions. In this case, benzene could be used to lower the BEC for Si in both on-mass and mass-shift measurements by nearly 3 orders of magnitude.

Publication Details

Journal
Repository for Publications and Research Data (ETH Zurich)
Published
2025-03-25
DOI
https://doi.org/10.3929/ethz-b-000727724
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ICPMS/MS with Benzene Vapor

Repository for Publications and Research Data (ETH Zurich)
Analytical chemistry methods development
article

ICPMS/MS with Benzene Vapor

article en

Abstract

Benzene vapor was introduced into the reaction cell of an inductively coupled plasma tandem mass spectrometer. By evaporating benzene into the helium supply of the octopole reaction cell, product ion spectra for plasma-based atomic and molecular ions were recorded. Based on these spectra, product ions for the separation of the atomic ions from spectral overlaps from isobaric or molecular ion interferents were selected. Background equivalent concentrations (BECs) or sensitivity ratios for analytes and interferents were compared to on-mass analyses without benzene addition. Depending on the analyte, up to 4 orders of magnitude improvement could be achieved. Specifically, the detection of S and Se could be improved substantially, and their BECs were reduced to the μg/L and ng/L ranges, respectively. The separation of isobaric Rb and Sr isotopes or of CeO+ from Gd+ was less effective with the use of benzene adducts alone. The separation could be substantially improved by using benzene and oxo or water adducts, and analyte/interferent sensitivity ratios greater than 104 were obtained. Finally, the attenuation of 14N2+, interfering with 28Si+, was evaluated under dry plasma conditions. In this case, benzene could be used to lower the BEC for Si in both on-mass and mass-shift measurements by nearly 3 orders of magnitude.

Repository for Publications and Research Data (ETH Zurich)
Clean water and sanitation
Openalex Percentile: Top 52%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ICPMS/MS with Benzene Vapor · Repository for Publications and Research Data (ETH Zurich) (2025) | TGRS Research Map | TGRS