A performance comparison between different PWM techniques for the Hybrid Inverter Drive

Variable Speed Drives (VSDs) allow energy savings for loads where operation below the grid frequency may be required. However, when operating the motor load at the grid frequency, they introduce, compared to grid-connected operation, energy losses and Electromagnetic Interference (EMI). The Hybrid Inverter Drive (HID) offers maximum efficiency at either mode of operation. With the HID the motor load is operated in inverter-driven mode for motor frequencies below grid frequency and operated in direct grid-connected mode for operation at grid frequency. This eliminates inverter losses and EMI at the grid frequency. In previous work [5], the HID and its semi-closed transitions were introduced. A performance comparison of the HID operation using pure Sinusoidal PWM (SPWM), Space Vector PWM (SVPWM) and the injection of the DC-link mid-point voltage into the SPWM reference signals during semi-closed transitions is presented in this paper. The HID is modelled in MATLAB Simulink.

Institutions

Publication Details

Journal
OAR@UM (University of Malta)
Published
2025-05-21
DOI
https://doi.org/10.34746/epe2025-0046
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A performance comparison between different PWM techniques for the Hybrid Inverter Drive

OAR@UM (University of Malta)
Microgrid Control and Optimization
article

A performance comparison between different PWM techniques for the Hybrid Inverter Drive

article en

Abstract

Variable Speed Drives (VSDs) allow energy savings for loads where operation below the grid frequency may be required. However, when operating the motor load at the grid frequency, they introduce, compared to grid-connected operation, energy losses and Electromagnetic Interference (EMI). The Hybrid Inverter Drive (HID) offers maximum efficiency at either mode of operation. With the HID the motor load is operated in inverter-driven mode for motor frequencies below grid frequency and operated in direct grid-connected mode for operation at grid frequency. This eliminates inverter losses and EMI at the grid frequency. In previous work [5], the HID and its semi-closed transitions were introduced. A performance comparison of the HID operation using pure Sinusoidal PWM (SPWM), Space Vector PWM (SVPWM) and the injection of the DC-link mid-point voltage into the SPWM reference signals during semi-closed transitions is presented in this paper. The HID is modelled in MATLAB Simulink.

OAR@UM (University of Malta)
University of Malta (MT)
Affordable and clean energy
Openalex Percentile: Top 46%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.