2,3,3,3‐Tetrafluorpropen

The German Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area has re‐evaluated the maximum concentration at the workplace (MAK value) of 2,3,3,3‐tetrafluoropropene [754‐12‐1]. As the blood:air partition coefficient of 2,3,3,3‐tetrafluoropropene is < 5, the increased respiratory volume at the workplace (see List of MAK and BAT Values, Sections I b and I c) does not have to be taken into account for the derivation of the MAK value. Moreover, the extrapolation of 6‐hour exposure in the animal experiment to 8‐hour exposure at the workplace does not need to be applied because the effect is much more dependent on the concentration than on time. The MAK value for 2,3,3,3‐tetrafluoropropene of 200 ml/m3 can therefore be retained.

Institutions

Publication Details

Journal
PUBLISSO
Published
2025-01-01
DOI
https://doi.org/10.34865/mb75412d0066_w
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

2,3,3,3‐Tetrafluorpropen

PUBLISSO
Indoor Air Quality and Microbial Exposure
article

2,3,3,3‐Tetrafluorpropen

article en

Abstract

The German Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area has re‐evaluated the maximum concentration at the workplace (MAK value) of 2,3,3,3‐tetrafluoropropene [754‐12‐1]. As the blood:air partition coefficient of 2,3,3,3‐tetrafluoropropene is < 5, the increased respiratory volume at the workplace (see List of MAK and BAT Values, Sections I b and I c) does not have to be taken into account for the derivation of the MAK value. Moreover, the extrapolation of 6‐hour exposure in the animal experiment to 8‐hour exposure at the workplace does not need to be applied because the effect is much more dependent on the concentration than on time. The MAK value for 2,3,3,3‐tetrafluoropropene of 200 ml/m3 can therefore be retained.

PUBLISSO
Karlsruhe Institute of Technology (DE), Akademie für Gesundheitsberufe (DE)
Openalex Percentile: Top 44%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.