VOC EMISSIONS FROM PARTICLE FILTERING HALF MASKS – METHODS, RISKS AND NEED FOR FURTHER ACTION

Investigations into volatile organic compound (VOC) emissions from polymer fleeces used in particle filtering half masks were conducted and evaluated against the German hygienic guide value for total volatile organic com- pounds and the “Lowest Concentration of Interest” for construction products. All masks showed emission of Xy- lene. In 94 % of samples, up to 24 additional aromatic compounds were found. 17 % of samples showed terpenes, 53 % emitted aldehydes, 77 % exhibited caprolactam and 98 % released siloxanes. All masks exceeded the TVOC hygienic guidance value level 5 of 10 mg/m³. Emission levels were investigated for masks immediately after their packages were opened and for masks that were “vented” for two weeks. Further, the emissions were repeatedly measured to investigate the decrease of emissions. An exponential decline was observed and a fitting function was calculated. The influence of the two commonly gas chromatograph (GC) hyphenated detectors, mass spectrometer (MS) and flame ionization detector (FID) on the VOC quantification, as well as the influence of temperature on the emission of VOCs were investigated. A statistical analysis of emission value differences for Notified Bodies was conducted and CE 2163 and 2020-1XG proved to be outliers.

Publication Details

Journal
FH Münster
Published
2025-01-01
DOI
https://doi.org/10.25974/fhms-19091
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

VOC EMISSIONS FROM PARTICLE FILTERING HALF MASKS – METHODS, RISKS AND NEED FOR FURTHER ACTION

FH Münster
Indoor Air Quality and Microbial Exposure
article

VOC EMISSIONS FROM PARTICLE FILTERING HALF MASKS – METHODS, RISKS AND NEED FOR FURTHER ACTION

article en

Abstract

Investigations into volatile organic compound (VOC) emissions from polymer fleeces used in particle filtering half masks were conducted and evaluated against the German hygienic guide value for total volatile organic com- pounds and the “Lowest Concentration of Interest” for construction products. All masks showed emission of Xy- lene. In 94 % of samples, up to 24 additional aromatic compounds were found. 17 % of samples showed terpenes, 53 % emitted aldehydes, 77 % exhibited caprolactam and 98 % released siloxanes. All masks exceeded the TVOC hygienic guidance value level 5 of 10 mg/m³. Emission levels were investigated for masks immediately after their packages were opened and for masks that were “vented” for two weeks. Further, the emissions were repeatedly measured to investigate the decrease of emissions. An exponential decline was observed and a fitting function was calculated. The influence of the two commonly gas chromatograph (GC) hyphenated detectors, mass spectrometer (MS) and flame ionization detector (FID) on the VOC quantification, as well as the influence of temperature on the emission of VOCs were investigated. A statistical analysis of emission value differences for Notified Bodies was conducted and CE 2163 and 2020-1XG proved to be outliers.

FH Münster
Openalex Percentile: Top 44%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.