Inference runtime of a neural network to detect atrial fibrillation on customized RISC-V-based hardware

As a common heart arrhythmia, atrial fibrillation(AF) is considered to be responsible for up to 15 % of allstrokes. For the diagnosis of AF, long term electrocardiogram(ECG) recordings are widely used. These recordings are ob-tained by Holter monitors or state-of-the-art patch ECG de-vices. Energy efficiency is of critical importance to enablethe use of the patch ECG devices for several days withoutchanging batteries or patches, while maintaining a small andlightweight design. Energy consumption of microcontrollersstrongly depends on their operating frequency. Hence theybenefit from a minimal software run time in clock cycles. Inthis work the impact of customized hardware in combinationwith structural optimization on inference runtime of a neu-ral network (NN), for the detection of AF and embedded ina patch ECG device, is investigated. The combination of opti-mized NN structure with the optimized hardware requires only13 % of the runtime compared to the original NN, while theaccuracy is increased by 0.5 percent points.

Publication Details

Journal
TUbilio (Technical University of Darmstadt)
Published
2025-01-01
DOI
https://doi.org/10.26083/tuprints-00029474
Primary Topic
Tree-ring climate responses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inference runtime of a neural network to detect atrial fibrillation on customized RISC-V-based hardware

TUbilio (Technical University of Darmstadt)
Tree-ring climate responses
article

Inference runtime of a neural network to detect atrial fibrillation on customized RISC-V-based hardware

article en

Abstract

As a common heart arrhythmia, atrial fibrillation(AF) is considered to be responsible for up to 15 % of allstrokes. For the diagnosis of AF, long term electrocardiogram(ECG) recordings are widely used. These recordings are ob-tained by Holter monitors or state-of-the-art patch ECG de-vices. Energy efficiency is of critical importance to enablethe use of the patch ECG devices for several days withoutchanging batteries or patches, while maintaining a small andlightweight design. Energy consumption of microcontrollersstrongly depends on their operating frequency. Hence theybenefit from a minimal software run time in clock cycles. Inthis work the impact of customized hardware in combinationwith structural optimization on inference runtime of a neu-ral network (NN), for the detection of AF and embedded ina patch ECG device, is investigated. The combination of opti-mized NN structure with the optimized hardware requires only13 % of the runtime compared to the original NN, while theaccuracy is increased by 0.5 percent points.

TUbilio (Technical University of Darmstadt)
Affordable and clean energy
Openalex Percentile: Top 45%
Tree-ring climate responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.