Einfluss der Scanbody-Geometrie und CAD-Software auf die Bestimmung der Implantatposition

The implementation of CAD software in the digital production of implant prosthetics stands as a pivotal aspect of clinical dentistry, necessitating high precision in the alignment of implant scanbodies. This study investigates the influence of scanbody geometry and the method of superimposing in CAD software when determining 3D implant position. A standardized titanium model with three bone-level implants was digitized to create reference STL files, and 10 intraoral scans were performed on Medentika and NT-Trading scanbodies. To determine implant position, the generated STL files were imported into the Exocad CAD software and superimposed—automatically and manually—with the scanbody geometries stored within the software’s shape library. Position accuracy was determined by a comparison of the 3D-defined scanbody points from the STL matching files with those from the reference STL files. The R statistical software was used for the evaluation of the data. In addition, mixed linear models and a significance level of 0.05 were applied to calculate the p-values. The manual overlay method was significantly more accurate than the automatic overlays for both scanbody types. The Medentika scanbodies showed slightly superior precision compared to the NT-Trading scanbodies. Both scanbody geometry and the type of alignment in the CAD software significantly affect digital workflow accuracy. Manual verification and adjustment of the automatic alignment process are essential for precise implant positioning.

Publication Details

Published
2025-01-01
DOI
https://doi.org/10.25593/open-fau-2151
Primary Topic
Geology and Paleoclimatology Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Einfluss der Scanbody-Geometrie und CAD-Software auf die Bestimmung der Implantatposition

Geology and Paleoclimatology Research
article

Einfluss der Scanbody-Geometrie und CAD-Software auf die Bestimmung der Implantatposition

article en

Abstract

The implementation of CAD software in the digital production of implant prosthetics stands as a pivotal aspect of clinical dentistry, necessitating high precision in the alignment of implant scanbodies. This study investigates the influence of scanbody geometry and the method of superimposing in CAD software when determining 3D implant position. A standardized titanium model with three bone-level implants was digitized to create reference STL files, and 10 intraoral scans were performed on Medentika and NT-Trading scanbodies. To determine implant position, the generated STL files were imported into the Exocad CAD software and superimposed—automatically and manually—with the scanbody geometries stored within the software’s shape library. Position accuracy was determined by a comparison of the 3D-defined scanbody points from the STL matching files with those from the reference STL files. The R statistical software was used for the evaluation of the data. In addition, mixed linear models and a significance level of 0.05 were applied to calculate the p-values. The manual overlay method was significantly more accurate than the automatic overlays for both scanbody types. The Medentika scanbodies showed slightly superior precision compared to the NT-Trading scanbodies. Both scanbody geometry and the type of alignment in the CAD software significantly affect digital workflow accuracy. Manual verification and adjustment of the automatic alignment process are essential for precise implant positioning.

Openalex Percentile: Top 47%
Geology and Paleoclimatology Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Einfluss der Scanbody-Geometrie und CAD-Software auf die Bestimmung der Implantatposition · (2025) | TGRS Research Map | TGRS