Field performance of a solar air heater used for space heating and ventilation – A case study in New Zealand primary schools

New Zealand (NZ) primary schools are inadequately ventilated in winter. The majority of NZ schools do not have mechanical ventilation systems and surveys show that only 30% of teachers are regularly opening windows in winter, therefore there is a need to study an affordable alternative ventilation method. This research was conducted to investigate the space heating and ventilation performance of a roof-mounted solar air heater (SAH) in NZ primary schools in winter. Field experiments over two winters were carried out in Palmerston North, NZ. A SAH was installed on the sun-facing roof of four schools in winter 2013 and six schools in winter 2014. During the experiment, the air temperature and air velocity were measured inside the classroom at the SAH outlet. Ambient weather conditions were measured by a local climate monitoring station. Across all schools and two winters, when the SAH was operated at 75% of the maximum fan speed, a mean (standard deviation, SD) level of the air temperature difference between the SAH outlet and inlet was 16.6 (10.4) °C, the mean (SD) volumetric flow rate of the outlet air was 34.0 (12.9) m3.h−1, and the mean (SD) level of thermal efficiency was 16 (11) %. Results showed that operating a roof-mounted SAH increased the indoor temperature and was useful to supplement the natural ventilation flow rate. This is the first study to investigate the field performance of a roof-mounted SAH in NZ primary schools over two winters. Results of this study provide insights for the use of solar energy without need for energy storage to heat and ventilate the classrooms.

Institutions

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.25455/wgtn.22806839
Primary Topic
Solar Energy Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Field performance of a solar air heater used for space heating and ventilation – A case study in New Zealand primary schools

Figshare
Solar Energy Systems and Technologies
article

Field performance of a solar air heater used for space heating and ventilation – A case study in New Zealand primary schools

article en

Abstract

New Zealand (NZ) primary schools are inadequately ventilated in winter. The majority of NZ schools do not have mechanical ventilation systems and surveys show that only 30% of teachers are regularly opening windows in winter, therefore there is a need to study an affordable alternative ventilation method. This research was conducted to investigate the space heating and ventilation performance of a roof-mounted solar air heater (SAH) in NZ primary schools in winter. Field experiments over two winters were carried out in Palmerston North, NZ. A SAH was installed on the sun-facing roof of four schools in winter 2013 and six schools in winter 2014. During the experiment, the air temperature and air velocity were measured inside the classroom at the SAH outlet. Ambient weather conditions were measured by a local climate monitoring station. Across all schools and two winters, when the SAH was operated at 75% of the maximum fan speed, a mean (standard deviation, SD) level of the air temperature difference between the SAH outlet and inlet was 16.6 (10.4) °C, the mean (SD) volumetric flow rate of the outlet air was 34.0 (12.9) m3.h−1, and the mean (SD) level of thermal efficiency was 16 (11) %. Results showed that operating a roof-mounted SAH increased the indoor temperature and was useful to supplement the natural ventilation flow rate. This is the first study to investigate the field performance of a roof-mounted SAH in NZ primary schools over two winters. Results of this study provide insights for the use of solar energy without need for energy storage to heat and ventilate the classrooms.

Figshare
Victoria University of Wellington (NZ)
Affordable and clean energy
Openalex Percentile: Top 54%
Solar Energy Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.