A line protection scheme for hybrid cascaded DC transmission systems based on boundary transient power direction

Due to the complex structure of hybrid cascaded DC transmission systems, a DC line protection scheme based on boundary transient power direction is proposed to enhance protection adaptability. First, the smoothing reactor serves as the boundary, enabling the derivation of transient power direction from voltages and currents on both sides of the reactor during line faults. Then, internal and external faults are identified by analyzing the characteristics of the boundary transient power direction, and the faulted pole is determined by comparing the summation of positive and negative boundary transient power values. Finally, the Baihetan-Jiangsu UHV hybrid cascaded DC transmission system is modeled using simulation software to verify the protection scheme. Results show that the proposed protection scheme can accurately identify internal and external faults within 6 ms and withstand transition resistances up to 600 Ω.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.19585/j.zjdl.202504003
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A line protection scheme for hybrid cascaded DC transmission systems based on boundary transient power direction

SHILAP Revista de lepidopterología
HVDC Systems and Fault Protection
article

A line protection scheme for hybrid cascaded DC transmission systems based on boundary transient power direction

article en

Abstract

Due to the complex structure of hybrid cascaded DC transmission systems, a DC line protection scheme based on boundary transient power direction is proposed to enhance protection adaptability. First, the smoothing reactor serves as the boundary, enabling the derivation of transient power direction from voltages and currents on both sides of the reactor during line faults. Then, internal and external faults are identified by analyzing the characteristics of the boundary transient power direction, and the faulted pole is determined by comparing the summation of positive and negative boundary transient power values. Finally, the Baihetan-Jiangsu UHV hybrid cascaded DC transmission system is modeled using simulation software to verify the protection scheme. Results show that the proposed protection scheme can accurately identify internal and external faults within 6 ms and withstand transition resistances up to 600 Ω.

SHILAP Revista de lepidopterología
Nanjing Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 54%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.