Particle measurement on all-metal gate valve for CEBAF beamline via laser-based particle counter
The Viton gate valves installed in the CEBAF beamline have significantly degraded after long-term operation in a radiation environment, generating numerous particles that cause heavy contamination and strong field emission. As a replacement, all-metal gate valves have been proposed for installation in the CEBAF beamline. In this paper, we present thorough comparison tests between the Viton gate valves and the all-metal gate valves, including evaluations of particle levels, aging tests of the gate valves, and analysis of the particle material.
Institutions
- Florida State University (US)
- Thomas Jefferson National Accelerator Facility (US)
Publication Details
- Journal
- JACOW
- Published
- 2024-10-25
- DOI
- https://doi.org/10.18429/jacow-linac2024-thpb080
- Primary Topic
- Emotion and Mood Recognition
- Type
- article
- Field-Weighted Citation Impact
- 0.00