Air disinfection effect of different human-machine coexistence disinfection methods

ObjectiveTo compare the air disinfection effects of different human-machine coexistence disinfection methods in the high-risk areas of airborne diseases in medical and healthcare institutions, and to provide a reference for the prevention and control of airborne diseases in medical and healthcare institutions.MethodsField trials were conducted in the fever clinic, the infection disease department, and dental clinics of a tertiary hospital in Shanghai, respectively. The existing air disinfection methods (plasma air disinfection machine, circulating air ultraviolet disinfection machine or negative pressure ventilation system), upper-room 222 nm ultraviolet germicidal system, and the combination of the existing air disinfection methods and upper-room 222 nm ultraviolet germicidal system were all used in each location in the experiment group. The control group did not adopt specific air disinfection methods. Air sampling was conducted by the six-level sieve hole microbial sampler or the flat slab exposure method. The daily air sampling time was from 8:00 a.m. to 16:00 p.m., with one sample per hour, and a total of 9 samples were taken. The disinfection effects were compared by calculating the total number of airborne bacteria colonies and the sterilization rate for each disinfection method.ResultsThe total numbers of airborne bacteria colonies in the fever outpatient infusion room, the ward and nurse station of infection disease department of 222 nm group were lower than that in the control group (P=0.005, P<0.001, P<0.001). The total numbers of airborne bacteria colonies in the fever outpatient infusion room and the dental examination room of 222 nm group were lower than that in the control group or plasma air disinfection machine group (P=0.022, P=0.014). The total numbers of airborne bacteria colonies in the nucleic acid sampling room of plasma air disinfection machine group combined with 222 nm group were lower than that in plasma air disinfection machine group (P=0.019). The total numbers of airborne bacteria colonies in the CT examination room of fever clinic of the 222 nm group were lower than that in the circulating air ultraviolet disinfection machine group (P=0.002). The total numbers of airborne bacteria colonies in the CT examination room of 222 nm group combined with circulating air ultraviolet disinfection machine were lower than that of circulating air ultraviolet disinfection machine group and the control group (P=0.008, P<0.001). The air sterilization rate of upper-room 222 nm ultraviolet germicidal system ranged from 48.04% to 73.74%. The air sterilization rate of plasma air/circulating air ultraviolet disinfection machine combined with the upper-room 222 nm ultraviolet germicidal system ranged from 6.86% to 73.77%.ConclusionUpper-room 222 nm ultraviolet germicidal system could effectively reduce airborne colonies in the air and improve air hygiene quality in both clinic and ward environments with high airborne transmission risks.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
DOI
https://doi.org/10.19428/j.cnki.sjpm.2024.24467
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Air disinfection effect of different human-machine coexistence disinfection methods

SHILAP Revista de lepidopterología
Infection Control and Ventilation
article

Air disinfection effect of different human-machine coexistence disinfection methods

article en

Abstract

ObjectiveTo compare the air disinfection effects of different human-machine coexistence disinfection methods in the high-risk areas of airborne diseases in medical and healthcare institutions, and to provide a reference for the prevention and control of airborne diseases in medical and healthcare institutions.MethodsField trials were conducted in the fever clinic, the infection disease department, and dental clinics of a tertiary hospital in Shanghai, respectively. The existing air disinfection methods (plasma air disinfection machine, circulating air ultraviolet disinfection machine or negative pressure ventilation system), upper-room 222 nm ultraviolet germicidal system, and the combination of the existing air disinfection methods and upper-room 222 nm ultraviolet germicidal system were all used in each location in the experiment group. The control group did not adopt specific air disinfection methods. Air sampling was conducted by the six-level sieve hole microbial sampler or the flat slab exposure method. The daily air sampling time was from 8:00 a.m. to 16:00 p.m., with one sample per hour, and a total of 9 samples were taken. The disinfection effects were compared by calculating the total number of airborne bacteria colonies and the sterilization rate for each disinfection method.ResultsThe total numbers of airborne bacteria colonies in the fever outpatient infusion room, the ward and nurse station of infection disease department of 222 nm group were lower than that in the control group (P=0.005, P<0.001, P<0.001). The total numbers of airborne bacteria colonies in the fever outpatient infusion room and the dental examination room of 222 nm group were lower than that in the control group or plasma air disinfection machine group (P=0.022, P=0.014). The total numbers of airborne bacteria colonies in the nucleic acid sampling room of plasma air disinfection machine group combined with 222 nm group were lower than that in plasma air disinfection machine group (P=0.019). The total numbers of airborne bacteria colonies in the CT examination room of fever clinic of the 222 nm group were lower than that in the circulating air ultraviolet disinfection machine group (P=0.002). The total numbers of airborne bacteria colonies in the CT examination room of 222 nm group combined with circulating air ultraviolet disinfection machine were lower than that of circulating air ultraviolet disinfection machine group and the control group (P=0.008, P<0.001). The air sterilization rate of upper-room 222 nm ultraviolet germicidal system ranged from 48.04% to 73.74%. The air sterilization rate of plasma air/circulating air ultraviolet disinfection machine combined with the upper-room 222 nm ultraviolet germicidal system ranged from 6.86% to 73.77%.ConclusionUpper-room 222 nm ultraviolet germicidal system could effectively reduce airborne colonies in the air and improve air hygiene quality in both clinic and ward environments with high airborne transmission risks.

SHILAP Revista de lepidopterología
Good health and well-being
Openalex Percentile: Top 45%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.