Multi-objective optimization of a portable air conditioner operating with R290 using genetic algorithms.

In the last years, the use of propane in air conditioning systems has increased. Major efforts are currently devoted to reducing the charge present in the systems to mitigate potential flammability issues due to leakages. In this view, the size reduction of the internal volumes of the heat exchangers is one of the most impacting strategies. Nevertheless, it is essential to optimize the heat exchangers so as not to compromise the system performance. This study presents an optimization of a portable air conditioner using multi-objective genetic algorithms. The objective is to minimize the refrigerant charge while maximizing the system performance. The fin-and-tube heat exchangers are modified in terms of outside diameter, transverse pitch, and tube length. The optimized system shows a reduction of the occupied volumes of 8% and a charge reduction of 36% while maintaining constant COP.

Publication Details

Journal
Virtual Community of Pathological Anatomy (University of Castilla La Mancha)
Published
2024-12-24
DOI
https://doi.org/10.18462/iir.gl2024.1193
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-objective optimization of a portable air conditioner operating with R290 using genetic algorithms.

Virtual Community of Pathological Anatomy (University of Castilla La Mancha)
Refrigeration and Air Conditioning Technologies
article

Multi-objective optimization of a portable air conditioner operating with R290 using genetic algorithms.

article en

Abstract

In the last years, the use of propane in air conditioning systems has increased. Major efforts are currently devoted to reducing the charge present in the systems to mitigate potential flammability issues due to leakages. In this view, the size reduction of the internal volumes of the heat exchangers is one of the most impacting strategies. Nevertheless, it is essential to optimize the heat exchangers so as not to compromise the system performance. This study presents an optimization of a portable air conditioner using multi-objective genetic algorithms. The objective is to minimize the refrigerant charge while maximizing the system performance. The fin-and-tube heat exchangers are modified in terms of outside diameter, transverse pitch, and tube length. The optimized system shows a reduction of the occupied volumes of 8% and a charge reduction of 36% while maintaining constant COP.

Virtual Community of Pathological Anatomy (University of Castilla La Mancha)
Affordable and clean energy
Openalex Percentile: Top 64%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.