Design of a Large Momentum Acceptance Gantry Based on AG-CCT for Lightweight Proton Therapy Facility

Superconducting (SC) gantry can be applied to proton therapy with significantly reduced footprint and weight. However, the relatively lower ramping limit of the SC magnetic field becomes a bottle-neck for fast energy change and beam delivery. The issue can be mitigated by designing a large momentum acceptance (LMA) beam optics. We present the design of an LMA gantry using AG-CCT SC magnets and symmetrical achromatic lattice. A fast degrader is combined in the design so that the gantry can rapidly switch energy during the treatment. The AG-CCT design process and beam transport simulation are all performed with our homemade integrated code CSPT, which has interfaces to Geant-4 and Opera, and can reach a maximum speed-up ratio of ~450 by applying parallel computation technique. The multi-particle simulation based on realistic field distribution proves that the gantry has a large momentum acceptance of ~20%. Due to its large momentum acceptance, the dispersion effect caused by the scanning magnet is not neglectable. A dispersion compensation method, accompanied by a compact nozzle layout, is proposed to achieve a scanning field of 25×25 cm² with a maximum beam energy spread of 5.2%.

Institutions

Publication Details

Journal
JACOW
Published
2025-05-22
DOI
https://doi.org/10.18429/jacow-sap2023-tupb014
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a Large Momentum Acceptance Gantry Based on AG-CCT for Lightweight Proton Therapy Facility

JACOW
Radiation Therapy and Dosimetry
article

Design of a Large Momentum Acceptance Gantry Based on AG-CCT for Lightweight Proton Therapy Facility

article en

Abstract

Superconducting (SC) gantry can be applied to proton therapy with significantly reduced footprint and weight. However, the relatively lower ramping limit of the SC magnetic field becomes a bottle-neck for fast energy change and beam delivery. The issue can be mitigated by designing a large momentum acceptance (LMA) beam optics. We present the design of an LMA gantry using AG-CCT SC magnets and symmetrical achromatic lattice. A fast degrader is combined in the design so that the gantry can rapidly switch energy during the treatment. The AG-CCT design process and beam transport simulation are all performed with our homemade integrated code CSPT, which has interfaces to Geant-4 and Opera, and can reach a maximum speed-up ratio of ~450 by applying parallel computation technique. The multi-particle simulation based on realistic field distribution proves that the gantry has a large momentum acceptance of ~20%. Due to its large momentum acceptance, the dispersion effect caused by the scanning magnet is not neglectable. A dispersion compensation method, accompanied by a compact nozzle layout, is proposed to achieve a scanning field of 25×25 cm² with a maximum beam energy spread of 5.2%.

JACOW
Huazhong University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 36%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.