Research on Reactive Power Coordination Control Scheme of Energy Feedback Device in Urban Rail Transit Power Supply System

Objective Currently, the urban rail transit power supply system mainly relies on the main substation SVG (static var compensator) for reactive power compensation. During non-operating hours at night, the medium voltage loop network lines of urban rail transit power supply system are basically unloaded, and the charging reactive power of the lines is high, causing SVG to operate under heavy load for a long time. To alleviate the compensation pressure of SVG, a reactive power coordination control scheme for energy feedback device is proposed, coordinating SVG and the energy feedback devices in the traction substation to jointly participate in reactive power compensation. Method The calculation method of the energy feedback device reactive power compensation capacity is analyzed, and the reactive power coordination control strategy for the SVG and energy feedback device is proposed. Finally, on-site tests on a certain metro line are performed, verifying the correctness of the above strategy. Result & Conclusion When the energy feedback devices of a metro line are all put into use for reactive power compensation, the SVG reactive power compensation capacity can be reduced by 2.6 Mvar to the most, and the total active power loss of the me-dium voltage loop network line can be reduced from 0.7 MW to about 0.5 MW.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
DOI
https://doi.org/10.16037/j.1007-869x.2024.09.034
Primary Topic
Railway Systems and Energy Efficiency
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Reactive Power Coordination Control Scheme of Energy Feedback Device in Urban Rail Transit Power Supply System

SHILAP Revista de lepidopterología
Railway Systems and Energy Efficiency
article

Research on Reactive Power Coordination Control Scheme of Energy Feedback Device in Urban Rail Transit Power Supply System

article en

Abstract

Objective Currently, the urban rail transit power supply system mainly relies on the main substation SVG (static var compensator) for reactive power compensation. During non-operating hours at night, the medium voltage loop network lines of urban rail transit power supply system are basically unloaded, and the charging reactive power of the lines is high, causing SVG to operate under heavy load for a long time. To alleviate the compensation pressure of SVG, a reactive power coordination control scheme for energy feedback device is proposed, coordinating SVG and the energy feedback devices in the traction substation to jointly participate in reactive power compensation. Method The calculation method of the energy feedback device reactive power compensation capacity is analyzed, and the reactive power coordination control strategy for the SVG and energy feedback device is proposed. Finally, on-site tests on a certain metro line are performed, verifying the correctness of the above strategy. Result & Conclusion When the energy feedback devices of a metro line are all put into use for reactive power compensation, the SVG reactive power compensation capacity can be reduced by 2.6 Mvar to the most, and the total active power loss of the me-dium voltage loop network line can be reduced from 0.7 MW to about 0.5 MW.

SHILAP Revista de lepidopterología
Sustainable cities and communities
Openalex Percentile: Top 48%
Railway Systems and Energy Efficiency
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.