Influence of DC-Bus Voltage on Synchronization Stability of Grid-Following Converters

With the increasing penetration of new energy sources and the development of new power systems, grid-following converter (GFL) plays a crucial role in maintaining the stability of power systems. However, existing transient stability analyses of GFLs assume that the direct current (DC) side behaves as a constant-voltage source, neglecting the effects of DC-bus voltage control. This paper aims to investigate the transient instability mechanism of GFL considering DC-bus voltage control. First, a transient synchronous stability model considering DC voltage control is established, followed by an analysis of the transient synchronous stability of GFL under DC-bus voltage control. The findings indicate that DC voltage control increases the active current reference value and decreases the equivalent damping of the GFL, which in turn reduces its transient synchronous stability of GFL. By increasing the proportional coefficient or reducing the integral coefficient of DC-bus voltage control, transient synchronous stability can be appropriately improved. Finally, the theoretical analysis is validated through MATLAB/Simulink simulations.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
DOI
https://doi.org/10.16183/j.cnki.jsjtu.2023.321
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of DC-Bus Voltage on Synchronization Stability of Grid-Following Converters

SHILAP Revista de lepidopterología
Microgrid Control and Optimization
article

Influence of DC-Bus Voltage on Synchronization Stability of Grid-Following Converters

article en

Abstract

With the increasing penetration of new energy sources and the development of new power systems, grid-following converter (GFL) plays a crucial role in maintaining the stability of power systems. However, existing transient stability analyses of GFLs assume that the direct current (DC) side behaves as a constant-voltage source, neglecting the effects of DC-bus voltage control. This paper aims to investigate the transient instability mechanism of GFL considering DC-bus voltage control. First, a transient synchronous stability model considering DC voltage control is established, followed by an analysis of the transient synchronous stability of GFL under DC-bus voltage control. The findings indicate that DC voltage control increases the active current reference value and decreases the equivalent damping of the GFL, which in turn reduces its transient synchronous stability of GFL. By increasing the proportional coefficient or reducing the integral coefficient of DC-bus voltage control, transient synchronous stability can be appropriately improved. Finally, the theoretical analysis is validated through MATLAB/Simulink simulations.

SHILAP Revista de lepidopterología
Xinjiang University (CN)
Affordable and clean energy
Openalex Percentile: Top 46%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of DC-Bus Voltage on Synchronization Stability of Grid-Following Converters · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS