Active Disturbance Rejection Control of Current of Direct Drive Wind Turbine in Power Grid Fault

The grid connection guidelines require wind turbines to have capability to quickly support reactive power in the events of grid faults. However, traditional proportional-integral controllers have the problems of slow transient response and poor adaptability dealing with changes in grid impedance and serious model disturbances. In order to solve this problem, this paper proposes an improved reactive power support control strategy which combines linear active disturbance rejection control(ADRC) with least error squares(LES) filters. The LES filter is used to quickly and accurately detect the amplitude of the fault grid voltage with background harmonics, which can effectively reduce the fault detection delay. The ADRC controller is used to effectively improve the transient reactive power response speed and the control adaptability and robustness of the wind turbines under grid impedance disturbance. The simulation model of direct drive wind turbine based on PSCAD/EMTDC is built considering two scenarios, weak power grid and power grid with background harmonics. The effectiveness of the proposed control strategy is verified by simulation.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
DOI
https://doi.org/10.16183/j.cnki.jsjtu.2023.159
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Active Disturbance Rejection Control of Current of Direct Drive Wind Turbine in Power Grid Fault

SHILAP Revista de lepidopterología
Wind Turbine Control Systems
article

Active Disturbance Rejection Control of Current of Direct Drive Wind Turbine in Power Grid Fault

article en

Abstract

The grid connection guidelines require wind turbines to have capability to quickly support reactive power in the events of grid faults. However, traditional proportional-integral controllers have the problems of slow transient response and poor adaptability dealing with changes in grid impedance and serious model disturbances. In order to solve this problem, this paper proposes an improved reactive power support control strategy which combines linear active disturbance rejection control(ADRC) with least error squares(LES) filters. The LES filter is used to quickly and accurately detect the amplitude of the fault grid voltage with background harmonics, which can effectively reduce the fault detection delay. The ADRC controller is used to effectively improve the transient reactive power response speed and the control adaptability and robustness of the wind turbines under grid impedance disturbance. The simulation model of direct drive wind turbine based on PSCAD/EMTDC is built considering two scenarios, weak power grid and power grid with background harmonics. The effectiveness of the proposed control strategy is verified by simulation.

SHILAP Revista de lepidopterología
Affordable and clean energy
Openalex Percentile: Top 65%
Wind Turbine Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.